Team:Grenoble/Biology/Protocols/PCR 1

From 2012.igem.org

(Difference between revisions)
(Created page with "{{:Team:Grenoble/Templates/Biology}} <html xmlns="http://www.w3.org/1999/xhtml" xml:lang="en" lang="en"> <body id="Biology"> <div id="cadre"> <section> <h1>PCR using a GoTaq...")
Line 5: Line 5:
<div id="cadre">
<div id="cadre">
<section>
<section>
-
     <h1>PCR using a GoTaq polymerase</h1>
+
     <h1>PCR using a GoTaq<span class="exposant">®</span> polymerase</h1>
     <h2>Goal</h2>
     <h2>Goal</h2>
     Amplify a section of DNA.
     Amplify a section of DNA.
Line 23: Line 23:
         <li>1.25 µL of reverse primer (10µM)</li>
         <li>1.25 µL of reverse primer (10µM)</li>
         <li>2.5 µL of dNTP (2 mM)</li>
         <li>2.5 µL of dNTP (2 mM)</li>
-
         <li>5 µL of GoTaq Reaction Buffer</li>
+
         <li>5 µL of GoTaq<span class="exposant">®</span> Reaction Buffer</li>
         <li>variable volume of template DNA</li>
         <li>variable volume of template DNA</li>
-
         <li>0.12 µL of GoTaq polymerase</li>
+
         <li>0.12 µL of GoTaq<span class="exposant">®</span> polymerase</li>
         <li>to 25 µL of nuclease-free water</li>
         <li>to 25 µL of nuclease-free water</li>
         </div>
         </div>

Revision as of 08:55, 3 September 2012

iGEM Grenoble 2012

Project

PCR using a GoTaq® polymerase

Goal

Amplify a section of DNA.

Protocol

Following are the instructions from the Promega website.

  1. Set up the thermocycler at the right temperatures.

  2. In a 50 µL PCR tube, introduce :
    • 1.25 µL of forward primer (10µM)
    • 1.25 µL of reverse primer (10µM)
    • 2.5 µL of dNTP (2 mM)
    • 5 µL of GoTaq® Reaction Buffer
    • variable volume of template DNA
    • 0.12 µL of GoTaq® polymerase
    • to 25 µL of nuclease-free water

    SAFETY AND USEFUL RECOMMANDATION
    Those products are not dangerous at first sight, but in case of spreading or in case of products on hands or on any parts on the body, it is recommended to wash this part and to dry it after. Be careful to use for each sample a different sterile cone. It is also important to well close tubes after putting the ingredient in. Moreover the DNA cannot resist until it is not incorporated in a plasmid and into a cell. Therefore there is no chance that there are any possible consequences because of a leakage in the environment.

  3. Put the 50 µL PCR tube into the thermocycler.

  4. Turn on the device.

  5. SAFETY AND USEFUL RECOMMANDATION
    It was noticed that it exists a certain number of different thermocycler models. That is why biologists do not know, all the time, how the device they will use, has to be manipulated. This can cause risks for thermocycler users. Indeed a thermocycler is an electric device which can become hot, and in case of misused people can be injured. Consequently it is very important for users to know how to use the device. It is recommended to read the operating instruction before using it. In our group we managed to learn how to use it before doing any manipulation. Besides on the device there are also protections to prevent accident.