Team:Grenoble/Biology/Protocols/PCR 1

From 2012.igem.org

(Difference between revisions)
 
(4 intermediate revisions not shown)
Line 7: Line 7:
     <h1>PCR using a GoTaq<span class="exposant">®</span> polymerase</h1>
     <h1>PCR using a GoTaq<span class="exposant">®</span> polymerase</h1>
     <h2>Goal</h2>
     <h2>Goal</h2>
-
     Amplify a section of DNA.
+
     Amplify a specific section of DNA.
</section>
</section>
<br/>
<br/>
Line 13: Line 13:
     <h2>Protocol</h2>
     <h2>Protocol</h2>
     Following are the instructions from the
     Following are the instructions from the
-
<a href="http://www.promega.com/~/media/files/resources/protocols/product%20information%20sheets/g/gotaq%20dna%20polymerase%20m300.pdf?la=en">Promega website</a>.
+
<a href="http://www.promega.com/~/media/files/resources/protocols/product%20information%20sheets/g/gotaq%20dna%20polymerase%20m300.pdf?la=en" target="blank">Promega website</a>.
<br/>
<br/>
<br/>
<br/>
Line 31: Line 31:
     <br/>
     <br/>
     <center>
     <center>
-
         <table>
+
         <table class="tableau">
                 <tr><th><i><div class="petit"><center>SAFETY AND USEFUL RECOMMANDATION</center></div></i></th></tr>
                 <tr><th><i><div class="petit"><center>SAFETY AND USEFUL RECOMMANDATION</center></div></i></th></tr>
                 <tr><td><div class="petit">Those products are not dangerous at first sight, but in case of spreading
                 <tr><td><div class="petit">Those products are not dangerous at first sight, but in case of spreading
Line 46: Line 46:
     <br/>
     <br/>
     <center>
     <center>
-
         <table>
+
         <table class="tableau">
                 <tr><th><i><div class="petit"><center>SAFETY AND USEFUL RECOMMANDATION</center></div></i></th></tr>
                 <tr><th><i><div class="petit"><center>SAFETY AND USEFUL RECOMMANDATION</center></div></i></th></tr>
                 <tr><td><div class="petit">It was noticed that it exists a certain number of different thermocycler models.
                 <tr><td><div class="petit">It was noticed that it exists a certain number of different thermocycler models.
-
                 That is why biologists do not know, all the time, how the device they will use, has to be manipulated. This
+
                 Each device has its own user guide which should be thoroughly read before using the device.  
-
                can cause risks for thermocycler users. Indeed a thermocycler is an electric device which can become hot,
+
The use of Thermocyclers can present risks. Indeed it is an electric device which can become very hot,
-
                 and in case of misused people can be injured. Consequently it is very important for users to know how to use
+
                 and in case of misused, people can be injured.</div></td></tr>
-
                the device. It is recommended to read the operating instruction before using it. In our group we managed to
+
-
                learn how to use it before doing any manipulation. Besides on the device there are also protections to prevent
+
-
                accident.</div></td></tr>
+
         </table>
         </table>
     </center>
     </center>

Latest revision as of 08:18, 25 September 2012

iGEM Grenoble 2012

Project

PCR using a GoTaq® polymerase

Goal

Amplify a specific section of DNA.

Protocol

Following are the instructions from the Promega website.

  1. Set up the thermocycler at the right temperatures.

  2. In a 200 µL PCR tube, introduce :
    • 1.25 µL of forward primer (10µM)
    • 1.25 µL of reverse primer (10µM)
    • 2.5 µL of dNTP (2 mM)
    • 5 µL of GoTaq® Reaction Buffer
    • variable volume of template DNA
    • 0.12 µL of GoTaq® polymerase
    • to 25 µL of nuclease-free water

    SAFETY AND USEFUL RECOMMANDATION
    Those products are not dangerous at first sight, but in case of spreading or contacts with any part of the body, it is recommended to wash this part and to dry it after. Use a different pipette tip for each sample. It is also important to close tubes after putting the different reagents. DNA is more sensitive to its environment while it is not circulared in a plasmid and introduced into a cell. Therefore, a spreading has very few chances to lead to any bad consequences.

  3. Put the 200 µL PCR tube into the thermocycler.

  4. Turn on the device.

  5. SAFETY AND USEFUL RECOMMANDATION
    It was noticed that it exists a certain number of different thermocycler models. Each device has its own user guide which should be thoroughly read before using the device. The use of Thermocyclers can present risks. Indeed it is an electric device which can become very hot, and in case of misused, people can be injured.