Team:Calgary/Notebook/Protocols/taqpcr

From 2012.igem.org

(Difference between revisions)
 
(11 intermediate revisions not shown)
Line 5: Line 5:
<p>The following is obtained from the Invitrogen Taq PCR kit (although most PCR kits have similar protocols).</p>
<p>The following is obtained from the Invitrogen Taq PCR kit (although most PCR kits have similar protocols).</p>
-
<center>
+
      <center>
<div style="margin-bottom:60px">
<div style="margin-bottom:60px">
   <table width="700">
   <table width="700">
     <tr>
     <tr>
-
      <td width="85%"><div class="heading"><p style="font-size:14px; font-weight:bold"><a style="text-decoration:none" name="pcr"></a>Taq PCR Protocol </p></div></td>
+
<td width="85%"><div class="heading"><center><h3></a>Mastermix setup</h3> </center></p></div></td>
     </tr>
     </tr>
   </table>
   </table>
Line 70: Line 70:
     </tr>
     </tr>
   </table>
   </table>
-
   <p><b> Thermocycler Conditions </b></p>
+
</center>
 +
   <p><i>Thermocycler Conditions</i></p>
   <ol>
   <ol>
-
     <li> 1 Cycle - 6 minutes at 95&deg;C </li>
+
     <li> 1 Cycle - 10 minutes at 95&deg;C </li>
     <li> 36 cycles of:
     <li> 36 cycles of:
       <ol>
       <ol>
-
         <li type="a"> 1 minute at 95&deg;C </li>
+
         <li type="a"> 3 minutes at 95&deg;C </li>
-
         <li type="a"> 1 minute at 58&deg;C (this step done at 65&deg;C for higher GC content ) </li>
+
         <li type="a"> 1 minute at 55&deg;C (for BioBrick primers) </li>
-
         <li type="a"> 1 minute at 72&deg;C </li>
+
         <li type="a"> 1 minute/kb at 72&deg;C </li>
       </ol>
       </ol>
     </li>
     </li>
Line 83: Line 84:
   </ol>
   </ol>
   <p> Conditions were varied as needed. For example in cases of longer products all 1 minute times were increased to 1.5 or even 3 minutes</p>
   <p> Conditions were varied as needed. For example in cases of longer products all 1 minute times were increased to 1.5 or even 3 minutes</p>
 +
<p>Follow the same protocol for a colony PCR.</p>
 +
 +
<p>We also used a Taq polymerase that we isolated in-house with slightly different cycling conditions. Since this Taq could not tolerate the lysis stage at 95&deg;C for 10 minutes, the cells were lysed in 4 μL of water for 10 minutes before master mix was added. 
</div>
</div>
</td>
</td>
</tr>
</tr>
-
</center>
+
 
-
<p>Follow the same protocol for a colony PCR.</p>
+
 
</html>}}
</html>}}

Latest revision as of 03:54, 4 October 2012

Hello! iGEM Calgary's wiki functions best with Javascript enabled, especially for mobile devices. We recommend that you enable Javascript on your device for the best wiki-viewing experience. Thanks!

Taq PCR Protocol

The following is obtained from the Invitrogen Taq PCR kit (although most PCR kits have similar protocols).

Mastermix setup

Reagent Volume ( 1x ) Volume ( 3x ) Volume ( 5x ) Volume ( 15x )
Sterile H2O 36 μL 108 μL 180 μL 540 μL
10X Taq Buffer 5 μL 15 μL 25 μL 75 μL
2mM dNTPs 5 μL 15 μL 25 μL 75 μL
Forward Primer (100 ug/ul) 1 μL 3 μL 5 μL 15 μL
Reverse Primer (100 ug/ul) 1 μL 3 μL 5 μL 15 μL
50mM MgCl2 1.5 μL 4.5 μL 7.5 μL 22.5 μL
Taq Polymerase (50 ug/ul) 0.5 μL 1.5 μL 2.5 μL 7.5 μL

Thermocycler Conditions

  1. 1 Cycle - 10 minutes at 95°C
  2. 36 cycles of:
    1. 3 minutes at 95°C
    2. 1 minute at 55°C (for BioBrick primers)
    3. 1 minute/kb at 72°C
  3. 1 Cycle - 10 minutes at 72°C then HOLD at 4°C

Conditions were varied as needed. For example in cases of longer products all 1 minute times were increased to 1.5 or even 3 minutes

Follow the same protocol for a colony PCR.

We also used a Taq polymerase that we isolated in-house with slightly different cycling conditions. Since this Taq could not tolerate the lysis stage at 95°C for 10 minutes, the cells were lysed in 4 μL of water for 10 minutes before master mix was added.