<p>Similar to when creating a standard curve potentiostatically the working electrode must be held at a specific oxidation potential for the detection of that analyte. Testing for this requires a culture of cells that will be able to report through a hydrolase enzyme. To perform the detection a three electrode setup will be needed.</p> | <p>Similar to when creating a standard curve potentiostatically the working electrode must be held at a specific oxidation potential for the detection of that analyte. Testing for this requires a culture of cells that will be able to report through a hydrolase enzyme. To perform the detection a three electrode setup will be needed.</p> | ||
- | < | + | <ol> |
- | <li>Pellet cells at 3750rpm for 10 minutes</li> | + | <li>Grow cells overnight in 3mL of LB.</li> |
- | <li>Remove supernatant</li> | + | <li>Pellet cells at 3750rpm for 10 minutes.</li> |
- | <li>Resuspend in 1mL of 0.1M pH7 PBS</li> | + | <li>Remove the supernatant.</li> |
- | <li>Add to 25mL 0.1M pH7 PBS in an electrochemical cell</li> | + | <li>Resuspend in 1mL of 0.1M pH7 PBS.</li> |
- | <li>Add the solution to be tested for activation of the reporter gene</li> | + | <li>Add to 25mL 0.1M pH7 PBS in an electrochemical cell.</li> |
- | <li>Add the electrodes and close the cell</li> | + | <li>Add the solution to be tested for activation of the reporter gene.</li> |
- | <li>Insert needle and bubble nitrogen or argon gas into the solution for 5 minutes</li> | + | <li>Add the electrodes and close the cell.</li> |
- | <li>Hold the working electrode at the oxidation potential for the analyte product</li> | + | <li>Insert a needle and bubble nitrogen or argon gas into the solution for 5 minutes.</li> |
- | <li>Wait 5 minutes for current stabilization</li> | + | <li>Hold the working electrode at the oxidation potential for the analyte product.</li> |
- | <li>Add the sugar-analyte substrate</li> | + | <li>Wait 5 minutes for current stabilization.</li> |
- | <li>Observe any current changes over a time period</li> | + | <li>Add the sugar-analyte substrate.</li> |
- | <li>Relate to concentration of analyte produced using a standard curve</li> | + | <li>Observe any current changes over a time period.</li> |
- | </ | + | <li>Relate to the concentration of the analyte produced using a standard curve.</li> |
+ | </ol> | ||
Revision as of 22:31, 3 October 2012
Hello! iGEM Calgary's wiki functions best with Javascript enabled, especially for mobile devices. We recommend that you enable Javascript on your device for the best wiki-viewing experience. Thanks!
Reporter Expression Detection
Similar to when creating a standard curve potentiostatically the working electrode must be held at a specific oxidation potential for the detection of that analyte. Testing for this requires a culture of cells that will be able to report through a hydrolase enzyme. To perform the detection a three electrode setup will be needed.
- Grow cells overnight in 3mL of LB.
- Pellet cells at 3750rpm for 10 minutes.
- Remove the supernatant.
- Resuspend in 1mL of 0.1M pH7 PBS.
- Add to 25mL 0.1M pH7 PBS in an electrochemical cell.
- Add the solution to be tested for activation of the reporter gene.
- Add the electrodes and close the cell.
- Insert a needle and bubble nitrogen or argon gas into the solution for 5 minutes.
- Hold the working electrode at the oxidation potential for the analyte product.
- Wait 5 minutes for current stabilization.
- Add the sugar-analyte substrate.
- Observe any current changes over a time period.
- Relate to the concentration of the analyte produced using a standard curve.