Team:Calgary/Notebook/Protocols/Carbazole GC-MS Analysis

From 2012.igem.org

(Difference between revisions)
Line 1: Line 1:
{{Team:Calgary/TemplateNotebookOrange|
{{Team:Calgary/TemplateNotebookOrange|
-
TITLE=Carbazole Degradation GC-MS Analysis|
+
TITLE=GC-MS Analysis|
CONTENT=<html>
CONTENT=<html>
-
<p> Following organic extraction of the carbazole-degrading cultures and controls, the samples were analyzed via autoinjection on an Agilent GC-MS system (model 7890A GC, model 5975C inert XL MSD) equipped with an HP-1 capillary column (50 m x 0.32 mm i.d. x 0.2 μm film, Agilent Technologies, Inc.).  The samples were analyzed in split mode (50:1 split), with the inlet held at 270°C.  The starting oven temperature was 160°C, held for 5 min, then increased at a rate of 4°C/min to 220°C.  The mass transfer line was held at 280°C.</p>
+
<p> Following organic extraction of the organic compound degrading cultures and controls, the samples were analyzed via autoinjection on an Agilent GC-MS system (model 7890A GC, model 5975C inert XL MSD) equipped with an HP-1 capillary column (50 m x 0.32 mm i.d. x 0.2 μm film, Agilent Technologies, Inc.).  The samples were analyzed in split mode (50:1 split), with the inlet held at 270°C.  The starting oven temperature was 160°C, held for 5 min, then increased at a rate of 4°C/min to 220°C.  The mass transfer line was held at 280°C.</p>
<p>After analysis, the peak areas under the carbazole and hexadecane (the extraction standard) were integrated using the Agilent Chemstation software.</p>   
<p>After analysis, the peak areas under the carbazole and hexadecane (the extraction standard) were integrated using the Agilent Chemstation software.</p>   

Revision as of 22:45, 3 October 2012

Hello! iGEM Calgary's wiki functions best with Javascript enabled, especially for mobile devices. We recommend that you enable Javascript on your device for the best wiki-viewing experience. Thanks!

GC-MS Analysis

Following organic extraction of the organic compound degrading cultures and controls, the samples were analyzed via autoinjection on an Agilent GC-MS system (model 7890A GC, model 5975C inert XL MSD) equipped with an HP-1 capillary column (50 m x 0.32 mm i.d. x 0.2 μm film, Agilent Technologies, Inc.). The samples were analyzed in split mode (50:1 split), with the inlet held at 270°C. The starting oven temperature was 160°C, held for 5 min, then increased at a rate of 4°C/min to 220°C. The mass transfer line was held at 280°C.

After analysis, the peak areas under the carbazole and hexadecane (the extraction standard) were integrated using the Agilent Chemstation software.