Team:OUC-China/Modeling/ODEModel

From 2012.igem.org

ODE Model

ODE simulation

Aim: To verify feasibility of ratio sensor & comparator theoretically

Steps:

1. Establish ODE equations based on Mass-action law;
2. Investigate reasonable parameter sets from previous researches;
3. Simulation;
4. Verify the feasibility of devices.

Results:Both Ratio Sensor and Comparator are feasible within the affordable range in vivo. However, the parameter space of Ratio sensor is not wide enough, which adds uncertainty on constructing such a device.

Background

Simulation based on mass-action law is a common method of modeling sRNA regulation[1]. Generally, we perform our simulation under the guidance given below



The differences on design between ratio sensor and comparator is noted in the project page.
Considering the RNA pairing reaction as chemical reaction,we will see the probability of collision is determined by their concentration, and the probability of pairing after collision is determined by their affinity(that is reaction constant k in mass-action law).



Noting that the input(extra inducer concentration) controls alphas & alpham(RNA synthesis rate), we formulated the mechanism above quantitatively via a simple kinetic model(ODE model) for three RNA interaction. The model is cast in terms of two mass-action equations for the cellular concentrations of the sRNA ([s1],[s2]) and its target GFP mRNA ([m]):





Is it feasible?In this ternary system,there are at least 6 parameters uncertain,we verified the feasibility of constructing such a device through ODE simulation using parameter set from previous researches, fortunately,it is viable theoretically within the affordable parameter range in cell, and the apparent enough with the presence of noise



ComparatorFor comparator, simple conclusions could be drawn:

When as1/as2>1, [m]steady state=0;
When as1/as2<1, [m]steady-state=60


Considering the mechanism of comparator as a molecular titration,we also expect a ultra-sensitivity behavior at the switch point(as1/as2=1),which will contribute to the “comparing” decision-making behavior.

Ratio sensorFor ratio sensor, an apparent peak can be observed when as1/as2=1 We run a supplementary simulation at point of as1:as2=1, making comparisons when as1:as2=1:1 and as1:as2=1:2(Fig.3)





Fig 3.



Discussion: The three differential equations are established based on Erel Levine et al and we have made a further development. In addition, our model has changed from the one for single interaction between sRNA and mRNA to the one for three kinds of interaction (s1RNA and s2RNA, s1RNA and mRNA, s2RNA and mRNA ). Therefore the latter model would come as a meaningful example for researchers to explore more interactions among RNAs. Of course, we can get the model, to a large degree, due to the creative achievement of Erel Levine et al and others.

References
[1] Levine, E., et al., Quantitative characteristics of gene regulation by small RNA. PLoS biology, 2007. 5(9)
[2] Nicolas E. Buchler1, Matthieu Louis, Molecular Titration and Ultrasensitivity in Regulatory Networks, J. Mol. Biol. (2008) 384, 1106–1119

Back to Top