This page gives you a first An impression on the concentrations condition in the european surface water. These data show, that our water is contaminated by several micro-contaminants. Some of them are found in a terrifying concentration in treated wastewater.
+
This page gives a first impression of the concentrations condition in the european surface water. These data show that our water is contaminated with several micro-contaminants. Some of them are found in a terrifying concentration in treated wastewater.
-
==micro-contaminants concentration of sewage effluent, surface water and==  
+
==Micro-contaminants concentration of sewage effluent and surface water==  
-
This assay results are collected byState Agency for Environment, Nature Conservation and Geology Mecklenburg-Vorpommern from the period 2008-2010. Data are shown of measurement of watersamples of sewage treatment plants and surface waters as part of a study given in order of the Federal Environment Agency (UBA-Germany).
+
This assay results were collected by the State Agency for Environment, Nature Conservation and Geology Mecklenburg-Vorpommern from the time period 2008-2010. Measured data from watersamples of sewage treatment plants and surface waters are shown as part of a study ordered by the Federal Environment Agency (UBA-Germany).
{| class="wikitable"
{| class="wikitable"

Revision as of 01:09, 27 September 2012

Concentration Data

This page gives a first impression of the concentrations condition in the european surface water. These data show that our water is contaminated with several micro-contaminants. Some of them are found in a terrifying concentration in treated wastewater.

Micro-contaminants concentration of sewage effluent and surface water

This assay results were collected by the State Agency for Environment, Nature Conservation and Geology Mecklenburg-Vorpommern from the time period 2008-2010. Measured data from watersamples of sewage treatment plants and surface waters are shown as part of a study ordered by the Federal Environment Agency (UBA-Germany).

Humanpharmaceuticals in clarifyed sewage Water and surface water in Mecklenburg-Vorpommern (Germany), average* und maximal in μg L -1 taken from [http://www.umweltbundesamt.de/chemikalien/veranstaltungen/ws-monitoring-arzneimittel/6_vortrag-abstract_bachor.pdf UBA-study]
Pharmaceuticals Sewage treat plant water (2008-2009) surface water (2008-2012)
middle max middle max
Carabamezipin 6.75 49.1 0.098 2.95
Diclofenac 2.63 10.5 0.063 1.95
Sulfamethoxazol 2.51 80.9 0.027 6.35
Metroprolol 2.4 10.7 0.037 1.04
Bisprolol 1.09 4.40 0.018 3.81
Sotalol 0.65 4.15 0.025 3.51
Ibuprofen 0.56 9.79 0.029 1.47
Bezafibrat 0.31 4.51 0.023 0.263
Propaolol 0.11 0.65 0.004 0.073
Phenazon 0.11 1.03 0.008 0.847
Atenolol 0.07 0.43 0.029 1.47
Propyphenanzon 0.02 0.46 0.004 0.022

Analysis finding of a cooperating sewage treatment plan

This micro-contaminant concentration are found in the clarifyed sewage water of the central sewage treatment plant of the city Schloß Holte-Stukenbrock (Germany) on 31.05.2012. The different micro-contaminants were detected by liquidchromatography-massspectroscopy (LC-MS) or liquidchromatography-massspectroscopy-massspectroscopy (LC-MS-MS). For the original document click here.

Micro contaminant-concentration in μg/l
micro-contaminants Concentration Analyse method
AcesulfamCarabamezipin 93 LC-MS
Sucralose 2.8 LC-MS
Clarithromycin 0.230 LC-MS-MS
Sulfamethoxazol 0.310 LC-MS-MS
N4-Acetylsulfamethoxazol 0.097 LC-MS-MS
Carabamazepin 1.2 LC-MS-MS
Diclofenac 1.9 LC-MS-MS
Benzotriazol 10.0 LC-MS
4-Methylbenzotriazol 2.10 LC-MS
5-Methylbenzotriazol 1.50 LC-MS
Metoprolol 2.50 LC-MS-MS
Sotalol 0.470 LC-MS-MS
Amidotrizoeacid 0.980 LC-MS-MS
Iomeprol 1.50 LC-MS-MS
Iopamidol 0.340 LC-MS-MS
Iopromid 0.110 LC-MS-MS