Team:TMU-Tokyo/Notebook/Experiment/4th week (9. 3 - 9. 9)

From 2012.igem.org

(Difference between revisions)
Line 62: Line 62:
<Br>
<Br>
<Br>
<Br>
-
Tuesday, 4th September
+
<b>■ 4th Sep<b/></p>
STEP 2: Construction of Device1
STEP 2: Construction of Device1
   Colony PCR of transformed E. coli (pfrm-frmR-GFP)
   Colony PCR of transformed E. coli (pfrm-frmR-GFP)
Line 68: Line 68:
   Failure: because of no bands
   Failure: because of no bands
-
Wednesday, 5th September
+
<b>■ 5th Sep<b/></p>
Ordered P.putida arrive
Ordered P.putida arrive
STEP 2: Construction of Device1
STEP 2: Construction of Device1
Line 85: Line 85:
   Success: 1 of 15 samples is appropriate band!
   Success: 1 of 15 samples is appropriate band!
-
Thursday, 6th September
+
<b>■ 6th Sep<b/></p>
STEP 2: Construction of Device1
STEP 2: Construction of Device1
   Colony PCR of transformed E. coli (pfrm-frmR-GFP)
   Colony PCR of transformed E. coli (pfrm-frmR-GFP)
Line 97: Line 97:
   Failure: because of no bands
   Failure: because of no bands
-
Friday, 7th September
+
<b>■ 7th Sep<b/></p>
STEP 1: Construction of Device3
STEP 1: Construction of Device3
   PCR of insert (fdh4AB)
   PCR of insert (fdh4AB)
Line 111: Line 111:
   Cultivation of P.putida (FDH) on plate
   Cultivation of P.putida (FDH) on plate
-
Sunday, 9th September
+
<b>■ 9th Sep<b/></p>
STEP 3: Construction of Device2
STEP 3: Construction of Device2
   PCR of insert (FDH)
   PCR of insert (FDH)

Revision as of 01:13, 26 September 2012

 


Experiment



■4th week (9. 3 - 9. 9)


■3rd September

STEP 1: Construction of Device3
PCR of insert (fdh4AB)
Electrophoresis
Failure: because of too dilute bands
PCR of insert (fdh4AB)
Electrophoresis
Failure: because of annealing temperature
PCR of insert (fdh4AB)
Electrophoresis
Success: We observed appropriate bands!


■ 4th Sep

STEP 2: Construction of Device1 Colony PCR of transformed E. coli (pfrm-frmR-GFP) Electrophoresis Failure: because of no bands ■ 5th Sep

Ordered P.putida arrive STEP 2: Construction of Device1 Electrophoresis Failure: because of no bands Colony PCR of transformed E. coli (pfrm-frmR-GFP) Electrophoresis Success: 2 of 15 samples are appropriate bands! Electrophoresis Failure: because of transformation miss Electrophoresis Failure: because of annealing temperature Electrophoresis Failure: because of annealing temperature Electrophoresis Success: 1 of 15 samples is appropriate band! ■ 6th Sep

STEP 2: Construction of Device1 Colony PCR of transformed E. coli (pfrm-frmR-GFP) Electrophoresis Failure: because of transformation miss Electrophoresis Failure: because of transformation miss STEP 1: Construction of Device3 Colony PCR of transformed E. coli (p-fdh4AB) Electrophoresis Failure: because of no bands ■ 7th Sep

STEP 1: Construction of Device3 PCR of insert (fdh4AB) Electrophoresis Success: We observed appropriate bands but a lot of smear. Electrophoresis Success: We observed appropriate bands! Colony PCR of transformed E. coli (p-fdh4AB) Electrophoresis Failure: because of PCR condition or ligation miss STEP 3: Construction of Device2 Preparation of culture plates for P.putida (FDH) Cultivation of P.putida (FDH) on plate ■ 9th Sep

STEP 3: Construction of Device2 PCR of insert (FDH) Electrophoresis Failure: because of no bands