Team:TMU-Tokyo/Notebook/Experiment/5th week (9.10 - 9.16)

From 2012.igem.org

(Difference between revisions)
Line 47: Line 47:
<b>■5th week (9.10 - 9.16)</b><Br></p>
<b>■5th week (9.10 - 9.16)</b><Br></p>
<Br>
<Br>
 +
<Br>
 +
<p class="description3">
 +
<b>■10th Sep</b><br /><Br>
 +
STEP 3: Construction of Device2<Br>
 +
  PCR of insert (FDH)<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of a lot of smear<Br>
 +
Ordered Device1 and Device2 plasmids arrive!<Br>
 +
<Br>
 +
<Br>
 +
<b>■11th Sep</b><br /><Br>
 +
STEP 1: Construction of Device3<Br>
 +
  PCR of insert (fdh4AB)<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of no bands<Br>
-
 
+
<b>■12th Sep</b><br /><Br>
 +
<Br>
 +
STEP 1: Construction of Device3<Br>
 +
  Colony PCR of transformed E. coli (p-fdh4AB)<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of transformation miss<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of transformation miss<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of transformation miss<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of transformation miss<Br>
 +
<Br>
 +
<Br>
 +
<b>■13th Sep</b><br /><Br>
 +
<Br>
 +
STEP 1: Construction of Device3<Br>
 +
  PCR of insert (fdh4AB)<Br>
 +
  Electrophoresis<Br>
 +
  Success: We observed appropriate bands but a lot of smear<Br>
 +
  Colony PCR of transformed E. coli (p-fdh4AB)<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of no appropriate bands<Br>
 +
<Br>
 +
<Br>
 +
<b>■14th Sep</b><br />
 +
New fdh4AB primers arrive<Br>
 +
STEP 1: Construction of Device3<Br>
 +
  PCR of insert (fdh4AB)<Br>
 +
  Electrophoresis<Br>
 +
  Failure: because of artificial mistake?<Br>
 +
  PCR of insert (fdh4AB)<Br>
 +
  Electrophoresis<Br>
 +
  Success: appropriate bands are clearer than before!<Br>
 +
<Br>
</p>
</p>
   </div>
   </div>

Revision as of 22:04, 25 September 2012

 


Experiment



■5th week (9.10 - 9.16)



■10th Sep

STEP 3: Construction of Device2
PCR of insert (FDH)
Electrophoresis
Failure: because of a lot of smear
Ordered Device1 and Device2 plasmids arrive!


■11th Sep

STEP 1: Construction of Device3
PCR of insert (fdh4AB)
Electrophoresis
Failure: because of no bands
■12th Sep


STEP 1: Construction of Device3
Colony PCR of transformed E. coli (p-fdh4AB)
Electrophoresis
Failure: because of transformation miss
Electrophoresis
Failure: because of transformation miss
Electrophoresis
Failure: because of transformation miss
Electrophoresis
Failure: because of transformation miss


■13th Sep


STEP 1: Construction of Device3
PCR of insert (fdh4AB)
Electrophoresis
Success: We observed appropriate bands but a lot of smear
Colony PCR of transformed E. coli (p-fdh4AB)
Electrophoresis
Failure: because of no appropriate bands


■14th Sep
New fdh4AB primers arrive
STEP 1: Construction of Device3
PCR of insert (fdh4AB)
Electrophoresis
Failure: because of artificial mistake?
PCR of insert (fdh4AB)
Electrophoresis
Success: appropriate bands are clearer than before!