15th Aug<br />
+
<b>■15th Aug</b><br />
-
Digestion<br />
+
<b>Digestion</b><br />
1. Mixed following<br />
1. Mixed following<br />
DW 15 μl<br />
DW 15 μl<br />
Line 82: Line 82:
5. Incubated at 37 °C for 1 hour 40 minutes.<br />
5. Incubated at 37 °C for 1 hour 40 minutes.<br />
<br />
<br />
-
Electrophoresis<br />
+
<b>Electrophoresis</b><br />
Put an agalose gel into the tank, and poured TBE buffer.<br />
Put an agalose gel into the tank, and poured TBE buffer.<br />
Mixed DNA samples: loading buffer = 9: 1. Loaded samples into wells.<br />
Mixed DNA samples: loading buffer = 9: 1. Loaded samples into wells.<br />
Electrophoresed, stopped when samples move to 2/3.<br />
Electrophoresed, stopped when samples move to 2/3.<br />
<br />
<br />
-
Gel extraction<br />
+
<b>Gel extraction</b><br />
Excised the DNA fragment from an agarose gel. For each 100 mg of agarose gel added 200 μl Buffer NT.<br />
Excised the DNA fragment from an agarose gel. For each 100 mg of agarose gel added 200 μl Buffer NT.<br />
Incubated sample for 5 – 10 minutes at 50 C. Vortexed the sample briefly every 2 – 3 minuets until the gel slice was completely dissolved.<br />
Incubated sample for 5 – 10 minutes at 50 C. Vortexed the sample briefly every 2 – 3 minuets until the gel slice was completely dissolved.<br />
Line 95: Line 95:
Placed the NucleoSpin Extract II Column into a new 1.5 ml microcetrifuge tube. Added 30 μl Buffer NE and incubated at room temperature for 1 minute. Centrifuged for 1 minute at 11,000 x g.<br />
Placed the NucleoSpin Extract II Column into a new 1.5 ml microcetrifuge tube. Added 30 μl Buffer NE and incubated at room temperature for 1 minute. Centrifuged for 1 minute at 11,000 x g.<br />
<br />
<br />
-
Densitometry<br />
+
<b>Densitometry</b><br />
Diluted DNA samples 50 times with a solvent.<br />
Diluted DNA samples 50 times with a solvent.<br />
Turned on the machine; GeneQuant 100.<br />
Turned on the machine; GeneQuant 100.<br />

Revision as of 13:57, 24 September 2012

 




■Experiment
1st week (8.13 - 8.19)
2nd week (8.20 - 8.26)
3rd week (8.27 - 9. 2)
4th week (9. 3 - 9. 9)
5th week (9.10 - 9.16)
6th week (9.17 - 9.23)
7th week (9.24 - 9.30)


■Protocols
Plasmid DNA Purification
Genome DNA Purification
Restruction Enzyme Degestion
DNA Fragment Ligation
Transformation
Electrophoresis
LB Medium


■Assay
Device1 Assay
Device2 Assay
Device3 Assay




Experiment



■1st week (8.13 - 8.19)


■15th Aug
Digestion
1. Mixed following
DW 15 μl
DNA solution 2 μl
10 x L buffer 2 μl
SacI 1 μl Total 20 μl
2. Incubated at 37 °C for 1 hour.
3. Heat inactivated at 65 °C for 10 minutes.
4. Mixed
DW 24 μl
Reaction solution 20 μl
10 x K buffer 5 μl
BamHI 1 μl Total 50 μl
5. Incubated at 37 °C for 1 hour 40 minutes.

Electrophoresis
Put an agalose gel into the tank, and poured TBE buffer.
Mixed DNA samples: loading buffer = 9: 1. Loaded samples into wells.
Electrophoresed, stopped when samples move to 2/3.

Gel extraction
Excised the DNA fragment from an agarose gel. For each 100 mg of agarose gel added 200 μl Buffer NT.
Incubated sample for 5 – 10 minutes at 50 C. Vortexed the sample briefly every 2 – 3 minuets until the gel slice was completely dissolved.
Placed a NucleoSpin Extract II Columu into a Collection Tube and loaded the sample. Centrifuged for 30 seconds at 11,000 x g. Discarded flow-through and placed the column backed into the collection tube.
Added 700 μl Buffer NT3 to the NucleoSpin Extact II Column. Centrifuged for 30 seconds at 11,000 x g. Discarded flow-through and placed the column backed into the collection tube.
Centrifuged for 1 minute at 11,000 x g to remove Buffer NT3 completely.
Placed the NucleoSpin Extract II Column into a new 1.5 ml microcetrifuge tube. Added 30 μl Buffer NE and incubated at room temperature for 1 minute. Centrifuged for 1 minute at 11,000 x g.

Densitometry
Diluted DNA samples 50 times with a solvent.
Turned on the machine; GeneQuant 100.
Poured the solvent 100 μl into a cuvette and adjusted 0.
Threw the solvent, poured the DNA sample.
Measured the concentration.

Results
Concentration of a back bone plasmid was 53 ng /μl.
We could not obtain the target fragments of fdh4AB.

16th Aug
Refine of PCR products: fdh4AB and Backbone plasmid
Mixed 1 volume of sample with 2 volumes of Buffer NT.
Placed a NucleoSpin Extract II Column into a Collection Tube and loaded the sample. Centrifuged for 30 seconds at 11,000 x g. Discarded flow-through and placed the column back into the collection tube.
Added 700 μl Buffer NT3 to the NucleoSpin Extract II Column. Centrifuged for 30 seconds at 11,000 x g. Discarded flow-though and placed the column back into the collection tube.
Centrifuged for 1 minute at 11,000 x g to remove Buffer NT3 completely.
Placed the NucleoSpin Extract II Column into a new 1.5 ml microcentrifuge tube. Added 30 μl Buffer NE and incubated at room temperature for 1 minute. Centrifuged for 1 minute at 11,000 x g.

Densitometry
Diluted DNA samples 50 times with a solvent.
Turned on the machine; GeneQuant 100.
Poured the solvent 100 μl into a cuvette and adjusted 0.
Threw the solvent, poured the DNA sample.
Measured the concentration.

Results
Concentration of fdh4AB was 210 ng/ μl.
Backbone plasmid No. 01 was 110 ng/ μl
No. 02 was 60 ng/ μl
Digestion
Mixed following
Fdh4AB
milliQ 6.5 μl
DNA solution 15 μl
10 x L buffer 2.5 μl
SacI 1 μl Total 25 μl
Backbone plasmid
milliQ 1.5 μl
DNA solution 20 μl
10 x L buffer 2.5 μl
SacI 1 μl Total 25 μl
2. Incubated for 1 hour at 37 °C.
3. Heat inactivated at 65 °C for 10 minutes.
4. Mixed following
milliQ 19 μl
Reaction solution 25 μl
10 x K buffer 5 μl
BamHI 1 μl Total 50 μl
5. Incubated at 37 °C for 1 hour.

Gel extraction
Excised the DNA fragment from an agarose gel. For each 100 mg of agarose gel added 200 μl Buffer NT.
Incubated sample for 5 – 10 minutes at 50 °C. Vortexed the sample briefly every 2 – 3 minuets until the gel slice was completely dissolved.
Placed a NucleoSpin Extract II Columu into a Collection Tube and loaded the sample. Centrifuged for 30 seconds at 11,000 x g. Discarded flow-through and placed the column back into the collection tube.
Added 700 μl Buffer NT3 to the NucleoSpin Extact II Column. Centrifuged for 30 seconds at 11,000 x g. Discarded flow-through and placed the column back into the collection tube.
Centrifuged for 1 minute at 11,000 x g to remove Buffer NT3 completely.
Placed the NucleoSpin Extract II Column into a new 1.5 ml microcentrifuge tube. Added 50 μl Buffer NE and incubated at room temperature for 1 minute. Centrifuged for 1 minute at 11,000 x g.

Results
We could not obtain the target band of fdh4AB.

Densitometry
Diluted DNA samples 50 times with a solvent.
Turned on the machine; GeneQuant 100.
Poured the solvent 100 μl into a cuvette and adjusted 0.
Threw the solvent, poured the DNA sample.
Measured the concentration.

Results
Concentration of backbone plasmid was 48 ng/ μl.

17th Aug
Electrophoresis of PCR products: before digestion of fdh4AB, after PCR products clean-up of fdh4AB, before PCR products clean-up of fdh4AB and diluted 100 times of PCR products of fdh4AB.

Put an agalose gel into the tank, and poured TBE buffer.
Mixed DNA samples: loading buffer = 9: 1. Loaded samples into wells.
Electrophoresed, stopped when samples move to 2/3.

Results
Every sample was smeared. It seemed that PCR didn’t run well.