Team:SDU-Denmark/labwork/Protocols

From 2012.igem.org

(Difference between revisions)
 
(10 intermediate revisions not shown)
Line 244: Line 244:
</br>
</br>
<!-- //////////// Tabel \\\\\\\\\\ -->
<!-- //////////// Tabel \\\\\\\\\\ -->
 +
<table>
<table>
Line 261: Line 262:
<tr>
<tr>
<td><a href="https://2012.igem.org/Team:SDU-Denmark/labwork/Protocols/revtrans">Reverse Transcriptase</a></td>
<td><a href="https://2012.igem.org/Team:SDU-Denmark/labwork/Protocols/revtrans">Reverse Transcriptase</a></td>
-
<td><a href="https://2012.igem.org/Team:SDU-Denmark/labwork/Protocols/mutagen">Mutagenisis</a></td>
+
<td><a href="https://2012.igem.org/Team:SDU-Denmark/labwork/Protocols/mutagen">Mutagenesis</a></td>
<td><a href="https://2012.igem.org/Team:SDU-Denmark/labwork/Protocols/pcrgelclean">PCR-,gel clean-up</a></td>
<td><a href="https://2012.igem.org/Team:SDU-Denmark/labwork/Protocols/pcrgelclean">PCR-,gel clean-up</a></td>
-
<td>Content</td>
+
 
</tr>
</tr>
-
</table>
+
</table>  
Line 273: Line 274:
<!-- /// velkomst ////-->
<!-- /// velkomst ////-->
-
<h2> Isolation of mRNA from <i>Helianthus tuberosus</i></h2> </b>
+
<h1> Isolation of mRNA from <i>Helianthus tuberosus</i></h1> </b>
<p>
<p>
(The procedure we used for mRNA isolation, is a modified version of the Qiagen RNeasy protocol for plant mRNA isolation.)
(The procedure we used for mRNA isolation, is a modified version of the Qiagen RNeasy protocol for plant mRNA isolation.)
Line 288: Line 289:
Transfer the samples to spin-column (Qiagen RNeasy mini kit, for RNA isolation from animal cells) in a 2mL sampletube and do the following:
Transfer the samples to spin-column (Qiagen RNeasy mini kit, for RNA isolation from animal cells) in a 2mL sampletube and do the following:
<p>
<p>
-
<ol>
+
1) Spin at 10.000 rmp for 15s, discard flowthrough add 700μL RW1 til spin column </br></br>
-
<li>Spin at 10.000 rmp for 15s, discard flowthrough
+
2) spin at 10.000 rmp for 15s, discard flowthrough add 500μL RPE buffer til spin column</br> (RPE buffer = 1:4 vol RPE/96-100% ethanol)</br>
-
add 700μL RW1 til spin column </li>
+
</br>
-
<li>spin at 10.000 rmp for 15s, discard flowthrough
+
3) spin at 10.000 rmp for 15s, discard flowthrough add another 500μL RPE buffer to the spin column (RPE buffer = 1:4 vol RPE/96-100% ethanol)</br>
-
add 500μL RPE buffer til spin column (RPE buffer = 1:4 vol RPE/96-100% ethanol)</li>
+
</br>
-
</li>
+
4) spin at 10.000 rmp for 15s, discard flowthrough Transfer the columns to new 2mL centrifuge tubes. Centrifuge at full speed for 1 min. Transfer spin columns to new 1.5mL sample tubes
-
<li> spin at 10.000 rmp for 15s, discard flowthrough
+
</br></br>
-
add another 500μL RPE buffer to the spin column (RPE buffer = 1:4 vol RPE/96-100% ethanol)
+
5) add 30-50μL RNase-free water and spin at 10.000 rpm for 60 seconds</br> </br>
-
</li>
+
6) Repeat the prior step once.
-
<li> spin at 10.000 rmp for 15s, discard flowthrough
+
</br>
-
Transfer the columns to new 2mL centrifuge tubes. Centrifuge at full speed for 1 min.
+
-
Transfer spin columns to new 1.5mL sample tubes </li>
+
-
<li> add 30-50μL RNase-free water <p></li>
+
-
<li> spin at 10.000 rpm for 60 seconds <p></li>
+
-
<li> Repeat the prior step once.</li>
+
-
</ol>
+
-
</p>
+
<p>
<p>
-
The mRNA is now isolated in the 60-100μL at the bottom of the collection tubes, and can be stored at -80C
+
The mRNA is now isolated in the 60-100μL at the bottom of the collection tubes, and can be stored at -80C.
-
</p>
+
</p></br> </br>
 +
<center><img src="https://static.igem.org/mediawiki/igem.org/8/8c/IGEM0852.jpg" width="100%" /></center>

Latest revision as of 00:15, 27 September 2012

iGEM TEAM ::: SDU-DENMARK courtesy of NIAID


mRNA Isolation PCR Miniprep Check Digest
3A-Assembly Colony-PCR Transformation Gel-electrophoresis
Reverse Transcriptase Mutagenesis PCR-,gel clean-up

Isolation of mRNA from Helianthus tuberosus

(The procedure we used for mRNA isolation, is a modified version of the Qiagen RNeasy protocol for plant mRNA isolation.)

Small tubers from Helianthus tuberosus were washed with untreated water and cut in rough slices with an everyday boxcutter.
The slices were distributed in cryotubes and weighed, the weights were noted down, and submerged in liquid nitrogen (flash-freeze at -196 °C). Flash-freezing is necessary to halt all RNase activity.
RLT buffer is mixed at this point, for later use. For each mL RLT, add μL beta-mercaptoethanol. Do this in a fume cabinet, as mercaptoethanol smells really bad and is toxic!
After 20 minutes 600mg is extracted from the cryotubes, the rest is stored for later use. The 600mg plant material is grinded to a fine dust using a mortar. It is important to keep the plant material frozen during the grinding, to keep the cell wall rigid enough to destroy it.
The plant powder is transferred to a tube and dissolved in RLT buffer(450μL buffer op 100mg plant material). We used approx. 3mL for 600mg material.
The solution is mixed using a vortex mixer.
500 μL of the solution is transfered to a 2mL treated with ultrasound to homogenize the content and further disrupt the cell wall. 500 μL is transfered to a 2mL tube as a control.
The samples are centrifuged at 14.500 rpm for 60 seconds to pellet out large organelles. 0,5 vol. 96-100% ethanol is added(250μL) to the sample, mixed by pipette.
Transfer the samples to spin-column (Qiagen RNeasy mini kit, for RNA isolation from animal cells) in a 2mL sampletube and do the following:

1) Spin at 10.000 rmp for 15s, discard flowthrough add 700μL RW1 til spin column

2) spin at 10.000 rmp for 15s, discard flowthrough add 500μL RPE buffer til spin column
(RPE buffer = 1:4 vol RPE/96-100% ethanol)

3) spin at 10.000 rmp for 15s, discard flowthrough add another 500μL RPE buffer to the spin column (RPE buffer = 1:4 vol RPE/96-100% ethanol)

4) spin at 10.000 rmp for 15s, discard flowthrough Transfer the columns to new 2mL centrifuge tubes. Centrifuge at full speed for 1 min. Transfer spin columns to new 1.5mL sample tubes

5) add 30-50μL RNase-free water and spin at 10.000 rpm for 60 seconds

6) Repeat the prior step once.

The mRNA is now isolated in the 60-100μL at the bottom of the collection tubes, and can be stored at -80C.