Team:SUSTC-Shenzhen-B/lab results
From 2012.igem.org
Line 32: | Line 32: | ||
<p> </p> | <p> </p> | ||
<h3 class="STYLE2"><font face="Arial, Helvetica">2. Fit curves relating to dscores and terminator efficiencies. </font></h3> | <h3 class="STYLE2"><font face="Arial, Helvetica">2. Fit curves relating to dscores and terminator efficiencies. </font></h3> | ||
+ | <p class="STYLE4"><span class="STYLE2"><img src=" https://static.igem.org/mediawiki/2012/6/6d/QQ%E6%88%AA%E5%9B%BE20120927115928.png" class="img_fl img_border" //font /></span></p> | ||
+ | <p class="STYLE3">(figure 6: Summary of results)</p> | ||
<p class="STYLE2"><img src="https://static.igem.org/mediawiki/2012/e/ec/91.png" class="img_fl img_border" //font /></p> | <p class="STYLE2"><img src="https://static.igem.org/mediawiki/2012/e/ec/91.png" class="img_fl img_border" //font /></p> | ||
<p class="STYLE3">(figure 3 : According the data on biofab ( <a href="http://io.biofab.org/services/studio/dac/">http://io.biofab.org/services/studio/dac/</a> ) and our software predicted dscores, create fit curves. Linear fit curve is founded to have the highest accuracy among all the fit curves. )</p> | <p class="STYLE3">(figure 3 : According the data on biofab ( <a href="http://io.biofab.org/services/studio/dac/">http://io.biofab.org/services/studio/dac/</a> ) and our software predicted dscores, create fit curves. Linear fit curve is founded to have the highest accuracy among all the fit curves. )</p> | ||
Line 40: | Line 42: | ||
<font face="Arial, Helvetica"></font> | <font face="Arial, Helvetica"></font> | ||
<div class="cleaner h40"></div> | <div class="cleaner h40"></div> | ||
- | + | ||
- | + | ||
<div class="cleaner"></div> | <div class="cleaner"></div> |
Revision as of 04:06, 27 September 2012
Result
1. Fluorescence microscope results
Our plasmid design contains a RFP and GFP. Fluorescence microscope pictures (Figure 1 and Figure 2) show that both GFP and RFP are expressed.(Figure 1: Those bacteria who express GFP and RFP are seen under the fluorescence microscope activated by 488nm light.The picture shows the expression of the RFP. )
(Figure 2: Those bacteria who express GFP and RFP are seen under the fluorescence microscope activated by 488nm light.The picture shows the expression of the GFP. )
2. Fit curves relating to dscores and terminator efficiencies.
(figure 6: Summary of results)
(figure 3 : According the data on biofab ( http://io.biofab.org/services/studio/dac/ ) and our software predicted dscores, create fit curves. Linear fit curve is founded to have the highest accuracy among all the fit curves. )
(figure 4 : According to our experiment measured terminator efficiencies and our software predicted dscores, we create fit curve to relate all the data . To correspond to the figure 3, we choose linear fit curve to link all the data. There are 5 valuable points of terminator efficiencies. The sequences are listed below. In the experiment, we transform 9 terminators to plasmid mutant-psb1a3-GF and only get 5 reliably terminators’ data. The points appeared on the figure are terminators whose number is 1,4,6,7,8 )
(figure 5 : Here listed the sequences of terminator whose efficiencies are measured in the lab.)