User:DrJones1935/15 August 2012
From 2012.igem.org
(Difference between revisions)
(Created page with "====I. Measure the Concentration of Extracted DNA==== *Bring samples and water upstairs to Take3 plate reader *Add 2 uL of each sample according to the following chart: {| class...") |
DrJones1935 (Talk | contribs) (→RESULTS) |
||
Line 14: | Line 14: | ||
=====''RESULTS''===== | =====''RESULTS''===== | ||
- | |||
''Concentration:'' | ''Concentration:'' |
Revision as of 01:41, 4 October 2012
Contents |
I. Measure the Concentration of Extracted DNA
- Bring samples and water upstairs to Take3 plate reader
- Add 2 uL of each sample according to the following chart:
Blank (water) | Blank |
Blank | Blank |
Digested Plasmid | Digested Cassette |
- Use the program to blank the machine and measure sample concentrations
RESULTS
Concentration:
Sample | Concentration (ng/uL) | Approx. volume (uL) | Approx. total (ug) |
---|---|---|---|
Digested Plasmid | 13.031 | ~28 | 0.365 |
Digested Cassette | 13.021 | ~28 | 0.365 |
II. Ligate Digested Plasmid and Digested Cassette Together
- 1:1 vector:insert ratio - Mix:
- 2 uL 10X T4 Buffer
- 6 uL plasmid DNA (~78 ng)
- 11 uL cassette DNA (~143 ng)
- 1 uL T4 Ligase
- 1:2 vector:insert ratio - Mix:
- 2 uL 10X T4 Buffer
- 3.64 uL plasmid DNA (~47 ng)
- 13.36 uL cassette DNA (~174 ng)
- 1 uL T4 Ligase
[http://molbiol.edu.ru/eng/scripts/h01_07.html This website] was helpful
- Incubate at room temperature for 2 hours, then David will use it to transform cells
III. Prepare for Gel Extraction of a PCR Product from 14 Aug 2012
- Make Gel:
- Measure out 0.40745 g of agarose and add to a 250 mL E-flask
- Add 50 mL of 0.5x TBE buffer and swirl to mix (0.8% gel)
- Cover flask with a Kimwipe and microwave for ~1 minute until clear
- Allow to cool to ~60 oC
- Immediately pour gel into tray with modified combs (2 taped together for large well)
- Allow to solidify, then remove the comb and tape and place the tray in the gel box with the wells closer to the black electrode
- Make sure it is submerged in TBE buffer
- Load Gel:
- Mix 4 samples (C1-4) in one tube with 20 uL loading dye. Load ~10 uL into one lane and the rest into another.
- Load on gel according to the following chart:
Lane 1 | 2 | 3-4 |
---|---|---|
NEB 2-log ladder (4 uL, premixed) | Cassette (~10 uL) | Cassette (~110 ul) |
- Run Gel:
- Close gel box and turn on power pack
- Run gel at 30 V for 26 min
- Run gel at 75 V until the markers have reached near bottom of the gel
- Cut Gel:
- Remove gel from box and cut along lanes to separate the 10 uL lane from the 110 uL lane.
- Return 110 uL lane to the gel box
- Post-stain with EtBr
- Place 10 uL lane in 200 mL of 0.5 ug/mL EtBr solution for 15 minutes
- Image Gel
- View 10 uL lane under UV to identify band of interest
- Use a clean razor blade to nick gel where the band is
- Excise Gel Fragments
- Match 110 uL lane to the 10 uL lane
- Using the 10 uL lane as a guide, cut out the band from the 110 uL lane
IV. QIAquick Gel Extraction Protocol
- Weigh each gel slice in a colorless microcentrifuge tube:
Cassette |
---|
376 mg |
- Add 3 volumes Buffer QG to 1 volume of gel
Cassette (+1) |
---|
1128 uL |
- Incubate in 50 oC water bath for 10-12 minutes until all gel has dissolved. Vortex to help mix.
- Note: The solutions were all yellow, OK to proceed
- Add 1 volume 100% isopropanol to samples and mix by inversion
Cassette (+1) |
---|
376 uL |
- Apply sample to a QIAquick column 800 uL at a time. Centrifuge for 1 minute at 13000 rpm, discard flow-through, and repeat until all of the sample has passed through the column
- Add 500 uL of Buffer QG to the QIAquick columns and centrifuge for 1 minute, discard flow-through
- Add 750 uL of Buffer PE to the QIAquick columns, centrifuge for 1 min and discard flow through
- Centrifuge again for 1 minute
- Transfer the columns to clean microcentrifuge tubes
- Elute DNA by adding 30 uL of Buffer EB to the center of the column and let stand for 4 minutes
- Centrifuge for 1 minute
V. Measure the Concentration of Extracted DNA
- Bring sample and Buffer EB bottle upstairs to Take3 plate reader
- Add 2 uL of each sample according to the following chart:
Blank (EB) | Blank |
Blank | Blank |
Cassette | (empty) |
- Use the program to blank the machine and measure sample concentrations
RESULTS
File: Media:srk_gel_extraction_15aug12.xlsx
Concentration:
Sample | Concentration (ng/uL) | Approx. volume (uL) | Approx. total (ug) |
---|---|---|---|
Cassette | 27.065 | ~28 | 0.76 |
VI. Image Post-Stained Gel
RESULTS
Source: Media:Srk_2012-08-15_17hr_55min.tif
Feature | Expected Size (bp) |
---|---|
Cassette | 5152 |