Team:Wageningen UR/Protocol/RoundupHepB
From 2012.igem.org
(Difference between revisions)
Jjkoehorst (Talk | contribs) (→Procedure) |
Jjkoehorst (Talk | contribs) (→Procedure) |
||
(One intermediate revision not shown) | |||
Line 17: | Line 17: | ||
<li>Gently put 4 mL of a 20% Sucrose in demiwater solution under the 4 mL sample</li> | <li>Gently put 4 mL of a 20% Sucrose in demiwater solution under the 4 mL sample</li> | ||
<li>Balance the vails with reassembly buffer</li> | <li>Balance the vails with reassembly buffer</li> | ||
- | <li>Centrifuge at 45000 | + | <li>Centrifuge at 45000 RPM for 3 h, remember the orientation of the vessel so you know where to look for the pellet</li> |
<li>Take a sample from the supernatant (for Western blotting) and decant the rest (supernatant also contains single subunits)</li> | <li>Take a sample from the supernatant (for Western blotting) and decant the rest (supernatant also contains single subunits)</li> | ||
<li>A transparent pellet should be visible</li> | <li>A transparent pellet should be visible</li> | ||
- | <li>Resuspend/ dissolve the pellet in 200 uL of Formation Buffer</li> | + | <li>Resuspend / dissolve the pellet in 200 uL of Formation Buffer</li> |
</ol> | </ol> |
Latest revision as of 01:04, 27 September 2012
Materials:
- Pipettes + Pipette tips
- Eppendorf tubes
- Greiner tubes
- Centrikon or a similar ultracentrifuge + all additional equipment
Procedure
- Cut the knot of the dialysis tubing and empty the content into a clean 50 mL Greiner tube
- Prepare a Centrikon T-1055 ultra-centrifugation vessel and use a TFT 65.13 rotor, fill the vails with 4 ml of the sample
- Gently put 4 mL of a 20% Sucrose in demiwater solution under the 4 mL sample
- Balance the vails with reassembly buffer
- Centrifuge at 45000 RPM for 3 h, remember the orientation of the vessel so you know where to look for the pellet
- Take a sample from the supernatant (for Western blotting) and decant the rest (supernatant also contains single subunits)
- A transparent pellet should be visible
- Resuspend / dissolve the pellet in 200 uL of Formation Buffer