Team:Wageningen UR/MethodsDetection
From 2012.igem.org
(→Detection of VLPs) |
(→Electron Microscopy (EM)) |
||
Line 14: | Line 14: | ||
Electron microscopy works similar as light microscopy, but instead of visible light being used to illuminate the sample, it is done by electrons. The EM has multiple lenses to focus the beam to magnify and light the sample. | Electron microscopy works similar as light microscopy, but instead of visible light being used to illuminate the sample, it is done by electrons. The EM has multiple lenses to focus the beam to magnify and light the sample. | ||
The lenses are electromagnetic instead of glass and therefore allow a much higher resolution than conventional light microscopy. In theory it is possible to reach a resolution of around 0.005 nm, but in practice it is mostly around 1-2 nm. Possible reasons are certain errors of the lenses, inexperience of the operator (for example our teammembers) or the sample is not thin enough. All these factors can reduce the resolution of the electron microscope. | The lenses are electromagnetic instead of glass and therefore allow a much higher resolution than conventional light microscopy. In theory it is possible to reach a resolution of around 0.005 nm, but in practice it is mostly around 1-2 nm. Possible reasons are certain errors of the lenses, inexperience of the operator (for example our teammembers) or the sample is not thin enough. All these factors can reduce the resolution of the electron microscope. | ||
- | + | ||
We investigated various samples obtained in our experiments with the help of the EM. The wild types of the Cowpea chlorotic mottle virus (CCMV) and Hepatitis B (HepB) were detected. Multiple variations of CCMV has been tested too unfortunateley with mixed results. | We investigated various samples obtained in our experiments with the help of the EM. The wild types of the Cowpea chlorotic mottle virus (CCMV) and Hepatitis B (HepB) were detected. Multiple variations of CCMV has been tested too unfortunateley with mixed results. | ||
[add pictures] | [add pictures] | ||
Line 32: | Line 32: | ||
At the end of the day we were able to prepare samples and visualize them in the EM. After the course, the attending team members were allowed and trained to use the EM without supervision. | At the end of the day we were able to prepare samples and visualize them in the EM. After the course, the attending team members were allowed and trained to use the EM without supervision. | ||
</p> | </p> | ||
+ | |||
== Dynamic Light Scattering (DLS) == | == Dynamic Light Scattering (DLS) == | ||
<p align="justify"> | <p align="justify"> |
Revision as of 21:10, 20 September 2012
Contents |
Detection of VLPs
A key part of our project is the detection of VLPs. We need sufficient visualization to get conclusive evidence of VLP formation. Besides, we will investigate alternative methods to detect the formation and stability of Virus-Like Particles.
Electron Microscopy (EM)
The most straight forward method to detect VLPs is Electron Microscopy (EM). We prepared and investigated multiple samples. This work was done at the Virology department of the Wageningen University. Media:EM vs LM Electron microscopy works similar as light microscopy, but instead of visible light being used to illuminate the sample, it is done by electrons. The EM has multiple lenses to focus the beam to magnify and light the sample. The lenses are electromagnetic instead of glass and therefore allow a much higher resolution than conventional light microscopy. In theory it is possible to reach a resolution of around 0.005 nm, but in practice it is mostly around 1-2 nm. Possible reasons are certain errors of the lenses, inexperience of the operator (for example our teammembers) or the sample is not thin enough. All these factors can reduce the resolution of the electron microscope. We investigated various samples obtained in our experiments with the help of the EM. The wild types of the Cowpea chlorotic mottle virus (CCMV) and Hepatitis B (HepB) were detected. Multiple variations of CCMV has been tested too unfortunateley with mixed results. [add pictures]
EM Course
We were instructed about the use of the EM by Jan van Lent at the Virology department of Wageningen UR. During the course he explained how the EM works, how you prepare the samples and how to operate the EM.
The goal of the course was to get familiar with the EM and to handle it safely. First there was a small presentation about how the EM works and how to prepare the samples. Next he showed us how to prepare a sample in practical after which we prepared our own samples.
Preparation of the sample is critical to have a good resolution, during the course we learned how to do it properly. The sample must be thin, between 2 - 300nm, and must be stable in the electron microscope. This can be done by drying or cryo-freezing the sample. After drying or freezing we stain the sample with a coating containing a heavy metal salt. The places where there is no coating (VLPs), electron wave can go through unhindered, while the places where there is coating, electron waves break apart. This result in an image which shows the VLPs.
After the preparation of the samples we were shown where the EM is and how to operate it. Again, he showed the procedures visualising one sample after which we were able to analyse the rest of the samples ourselves.
(SLIDE SHOW EM PICTURES)
At the end of the day we were able to prepare samples and visualize them in the EM. After the course, the attending team members were allowed and trained to use the EM without supervision.
Dynamic Light Scattering (DLS)
Another method to detect virus-like-particles is with dynamic light scattering (DLS), also known as photon correlation spectroscopy or quasi-elastic light scattering. This technique is used to measure the size of particles and is thus an indirect way to detect particles. We used this technique as a complimentary method next to the electron microscopy.
Media:(PICTURE DLS OVERVIEW)
When light travels through the sample and hits a particle, light will scatter in all directions. The dynamic light scattering machine detects the scattered light under a fixed angle. The particles in the solution will move randomly due to Brownian motion. As the particles move, the intensity will change. This is because the scattered light can undergo constructive or deconstructive interference with the scattered light of other particles. The larger the particle, the more slower it is in Brownian motion, the slower the change of intensity is. The change in intensity over time relates to the diffusion coefficient and this diffusion coefficient is related to the particle radius using the Stokes-Einstein equation.
We tested multiple samples with DLS. The main issue was that the sample was not pure enough or not concentrated enough. After optimizing the production and purification protocol we succeeded to detect VLPs. The main improvement was the implementation of FPLC, which filters out all aggregates and subunits, yielding pure VLP solutions.
Sources:
EM
- Jan van Lent
- Quantitative characterization of virus-like particles by asymmetrical flow field flow fractionation, electrospray differential mobility analysis, and transmission electron microscopy - Leonard F. Pease, Daniel I. Lipin, De-Hao Tsai, Michael R. Zachariah, Linda H.L. Lua, Michael J. Tarlov, Anton P.J. Middelberg
DLS
- Remco Fokkink
- Light Scattering from Polymer Solutions and Nanoparticle Dispersions - Wolfgang Schartl
- Nanoparticle-Templated Assembly of Viral Protein Cages - Chao Chen, Marie-Christine Daniel, Zachary T. Quinkert, Mrinmoy De, Barry Stein, Valorie D. Bowman, Paul R. Chipman, Vincent M. Rotello, C. Cheng Kao, and Bogdan Dragnea