User:DrJones1935/30 July 2012

From 2012.igem.org

Contents

I. Prepare for Gel Extraction of a PCR Product from 27 Jul 2012

  • Make Gel:
  • Measure out 0.75 g of agarose and add to a 250 mL E-flask
  • Add 75 mL of 0.5x TBE buffer and swirl to mix
  • Cover flask with a Kimwipe and microwave for ~1 minute until clear
  • Allow to cool to ~60 oC
  • Immediately pour gel into tray with combs
  • Allow to solidify, then remove the comb and tape and place the tray in the gel box with the wells closer to the black electrode
  • Make sure it is submerged in TBE buffer
  • Note: Some gel leaked out the ends
  • Load Gel:
  • Mix sample in PCR tubes with 10 uL buffer. Load 40 uL into one lane and the rest into another.
  • Load on gel according to the following chart:
Lane 1 2 3
Invitrogen 1kb+ ladder +1 (~10 uL) +1 (~40 ul)
  • Run Gel:
  • Close gel box and turn on power pack
  • Run gel at 30 V for a while to stack gel (while at lunch)
  • Run gel at 75 V until the markers have reached ~3/4 down the gel
  • Cut Gel:
  • Remove gel from box and cut along lanes to separate the 10 uL lane from the 40 uL lane.
  • Return 40 uL lane to the gel box
  • Post-stain with EtBr
  • Place 10 uL lane in 200 mL of 0.5 ug/mL EtBr solution for 15 minutes
  • Remove EtBr solution and wash with 200 mL of dH2O for 10 minutes
  • Image Gel
  • View 10 uL lane under UV to identify band of interest
  • Use a clean razor blade to nick gel where the band is
  • Excise Gel Fragments
  • Match 40 uL lane to the 10 uL lane
  • Using the 10 uL lane as a guide, cut out the band from the 40 uL lane

II. QIAquick Gel Extraction Protocol

  • Weigh each gel slice in a colorless tube:
Cassette (+1)
389 mg
  • Add 3 volumes Buffer QG to 1 volume of gel
Cassette (+1)
1167 uL
  • Incubate in 50 oC water bath for 10-12 minutes until all gel has dissolved. Vortex to help mix.
  • Note: The solutions were all yellow, OK to proceed
  • Add 1 volume 100% isopropanol to samples and mix by inversion
Cassette (+1)
389 uL
  • Apply sample to a QIAquick column 800 uL at a time. Centrifuge for 1 minute at 13000 rpm, discard flow-through, and repeat until all of the sample has passed through the column
  • Add 500 uL of Buffer QG to the QIAquick columns and centrifuge for 1 minute, discard flow-through
  • Add 750 uL of Buffer PE to the QIAquick columns and let the column stand for 5 minutes on the bench
  • Centrifuge for 1 min and discard flow through
  • Centrifuge again for 1 minute
  • Transfer the columns to clean microcentrifuge tubes
  • Elute DNA by adding 30 uL of Buffer EB to the center of the column and let stand for 4 minutes
  • Centrifuge for 1 minute

III. Measure the Concentration of Extracted DNA

  • Bring sample and Buffer EB bottle upstairs to Take3 plate reader
  • Add 2 uL of each sample according to the following chart:
Blank (EB) Blank
Blank Blank (diverging, ignored)
Cassette (empty)
  • Use the program to blank the machine and measure sample concentrations
RESULTS

Concentration:

Sample Concentration (ng/uL) Approx. volume (uL) Approx. total (ug)
Cassette 0 ~28 0

IV. Image Post-Stained Portion of Gel

RESULTS
Srk 2012-07-30 15hr 02min.jpg

Source: Media:Srk_2012-07-30_15hr_02min.tif

Feature Expected Size (bp)
Cassette 5152