Morning: Cell counting and sampling
- Cell counting
Given our cell density, we used a 12x dilution (table). We transfered 6 samples of cells into a 96 well plate, added Trypan blue and analyzed each sample with Countess.
Sample # | Viable cells | Dead cells | Viability | Total cells |
1 | 182 | 12 | 94% | 194 |
3 | 112 | 7 | 94% | 119 |
5 | 124 | 8 | 94% | 132 |
7 | 129 | 16 | 89% | 145 |
9 | 170 | 3 | 98% | 173 |
11 | 127 | 9 | 93% | 136 |
- Average cell # for samples 3.5.7 = 122 cells
- LCD: 122*12/400 = 3.66 mio cells/ml
-> we need to take 1.37ml to obtain 5 mio cells.
- Comments
Sample 7 has been excluded because of bubble-like structures which appeared while scanning and were confused with cells clusters by the program.
- Western Blot sampling
Protocol:
- Centrifugation of the cell samples at 2500xg for 10min. Discard the supernatant (vacuum).
- Washing: Resuspend the pellet in PBS1x, centrifuge at 2500xg for 10min, discard supernatant.
- Add at least 1mL PER-M Reagent for 100mg (~100µl) of cell pellet. Pipette up and down to suspend.
- Shake gently for 10min.
- Remove cell debris by centrifugation: ~1400xg for 15min
- Transfer the supernatant into new tubes for analysis or storage.
- Samples were taken from odd numbered tubes : 1, 3, 5, 7.
- We used 300µl of M-PER Reagent based on the size of our pellets.
- Maximum centrifugation was 10'600xg.
- Comments
For samples 3 and 5 we had to repeat step 5 (centrifugation to remove cell debris) because the cell pellet got aspired in the pipette while trying to transfer the supernantant into fresh tubes.
Afternoon: Cell lysates
We prepared cell lysates for future mRNA sampling and for analysing fluorescence the same day.
- The results from the Tecan plate reader did not show any significant increase in red fluorescence for co-transfected cells. We were also not able to detect intrinsic fluorescence in the range of the Lov domain.
Protocol: Sampling for mRNA
- Take ~1mio cells in 750 µl PBS
- Centriguge samples at 450xg for 5min
- Remove the supernatant (vaccum) leaving 50µl.
- Vortex and resuspend.
- Add 1µl PBS, vortex again.
- Centrifuge at 450xg for 5min
- Remove supernatant (pipette) and freeze in liquid nitrogen. Store at -20°C.
- Passaging
Our cell density was 6 mio cells/ml, therefore we needed to take a volume of 170 µl to have 1 mio cells/ml.