Team:EPF-Lausanne/Modeling/Bioreactor

From 2012.igem.org

(Difference between revisions)
(Replaced content with "{{:Team:EPF-Lausanne/Template/Header|project}} == Cell culture absorbance test == Raw results in File:Team-EPF-Lausanne-cell-culture-absorbance-nanodrop.pdf. {{:Team:...")
 
(One intermediate revision not shown)
Line 1: Line 1:
{{:Team:EPF-Lausanne/Template/Header|project}}
{{:Team:EPF-Lausanne/Template/Header|project}}
-
= Illumination =
 
-
 
-
In Strickland's paper, it's mentioned that they used 8000 mcd LEDs from [http://www.theledlight.com theledlight.com], with 20º viewing angle and 468 nm at 3.4 V.
 
-
 
-
It's also mentioned that a single LED was used per tube, with a cross section of 0.12 cm<sup>2</sup> = 1.2x10<sup>-5</sup> m<sup>2</sup>.
 
-
 
-
20º viewing angle, 0.35 rad, means a solid angle of 2π(1-cos(0.35)) = 0.381 sr.
 
-
 
-
This gives a luminous flux of 0.381*8 = 3.05 lm per LED.
 
-
 
-
The illuminance they used was then 3.05/1.2x10<sup>-5</sup> = 2.54x10<sup>5</sup> lux (or lm/ m<sup>2</sup>).
 
-
 
-
A bioreactor that has some 0.2*π*0.3 = 0.19 m<sup>2</sup>, we would need at least 2.54x10<sup>5</sup> * 0.19 = 48260 lm, or some 16000 LEDs just to make sure the outer surface of the bioreactor has the same light conditions!!
 
-
 
-
This doesn't take into account reflections in the bioreactor, so I hope it will lower this number.
 
-
 
-
== Illuminance test ==
 
-
 
-
We can try first different illuminance values, to get an idea about the range in which the LovTAP-VP16 switch saturates. This could be done by using cylindrical cell culture test plates (there are two sizes: 8.96 sqcm and 3.60 sqcm of circular base).
 
-
 
-
If we take the one with 3.60 sqcm (or 2.14 cm in diameter), considering we have 20º LEDs, the distance between the well bottom and the LED has to be of around 6 cm to have the whole well illuminated.
 
-
 
-
But, attention! This will be some 20 times less illuminance than in Strickland's experiment!
 
-
 
-
If we take the plates with 24 wells, or 1.86 cm2 the well, or 1.54 cm in diameter: the distance from LED to well bottom should be around 4.4 cm. The height of the plates is 22 mm, perfect!
 
== Cell culture absorbance test ==