Team:Cambridge/Protocols/PCRcolony
From 2012.igem.org
Home | Team | Official Team Profile | Project | Parts Submitted to the Registry | Modeling | Notebook | Safety | Attributions | Sponsors |
---|
Colony PCR:
Used to amplify DNA directly from cell culture, the reaction is the same as for normal PCR but with modified reaction composition and cycle settings, here shown for a 50 µl reaction using Taq polymerase.
Reagent | Volume (µl) | Final Concentration |
Water | 35.7 | |
10 mM dNTPs | 1 | 200 µM |
10 x NH4 buffer | 5 | 1x |
Forward Primer | 2.5 | 0.5 µM |
Reverse Primer | 2.5 | 0.5 µM |
Template Cells | 1.3 (from liquid culture or picked colony | |
Taq polymerase 5u/µl | 1 | 0.1 u/ µl |
PCR machine settings:
Temperature (oc) | Time (s) | ||
Step 1 (cell breakage) | 95 | 360 | |
Step 2 (Cycle 30x) | Denaturing | 98 | 10 |
Annealing | 60 | 30 | |
Elongation | 72 | 120 | |
Step 3 (final extension) | 72 | 300 |
Safety considerations: It is important to observe correct laboratory procedure and wear appropriate clothing and gloves. PCR occurs at high temperature and this may present a risk, depending on the PCR machine employed. For handling the cell culture, appropriate measures should be in place to deal with biohazardous waste.