Chemically competent E. coli cells production
Goal
Product E. coli cells which are competent for transformation.Protocol
Following are the instructions from the OpenWetWare website.- Grow a 5 mL overnight culture of cells in LB media. In the morning, dilute this culture back into 25-50 mL of fresh LB media in a 200 mL conical flask. You should aim to dilute the overnight culture by at least 1/100.
- Grow the diluted culture to an OD600 of 0.2 - 0.5. (You will get a very small pellet if you grow 25 mL to OD600 0.2).
- Put eppendorf tubes on ice now so that they are cold when cells are aliquoted into them later. If your culture is X ml, you will need X tubes. At this point you should also make sure that your TSS is being chilled (it should be stored at 4°C but if you have just made it fresh then put it in an ice bath).
- Split the culture into two 50ml falcon tubes and incubate on ice for 10 min.
SAFETY AND USEFUL RECOMMANDATIONS |
---|
This step must be done under a flow hood.
The flow hood must be sterile, therefore, it is recommended to activate the
venting system before opening the flow closet.
In case of any doubts, use the UV lamp to sterilize the working space . |
SAFETY AND USEFUL RECOMMANDATIONS |
---|
There is no significant risk in using the device,
but before making any measurments, users must know how they have to manipulate it. |
SAFETY AND USEFUL RECOMMANDATIONS |
---|
In order to reduce the risk of ice that could fall, it is
recommended to place the back near the place manipulations and in case of any move,
it is better to take eppendorfs in an eppendorf rack. That is why it is important to
know where manipulations will be done. Tubes must also be sterile and no where be open
except under the flow hood. |
All subsequent steps should be carried out at 4°C and the cells should be kept on ice as much as possible.
SAFETY AND USEFUL RECOMMANDATIONS |
---|
All manipulations are done in cold atmosphere. That is why ice is used.
The ice has to be correctly put in backs which should not be moved, to prevent it from falling. It is also recommended to change gloves every 30 minutes. |
- Centrifuge for 10 minutes at 3000 rpm and 4°C.
- Remove supernatant. The cell pellets should be sufficiently solid so that you can just discard the supernatant if you are careful. Pipette out any remaining media.
- Resuspend in chilled TSS buffer. The volume of TSS to use is 10% of the culture volume that you spun down. You may need to vortex gently to fully resuspend the culture, keep an eye out for small cell aggregates even after the pellet is completely off the wall.
- Add 100 µL aliquots to your chilled eppendorfs and store at -80°C.
SAFETY AND USEFUL RECOMMANDATIONS |
---|
The centrifuge must be balanced before being switched on.
If the device is malfunctioning, it must not be used. |