Team:Bielefeld-Germany/Results/substrate

From 2012.igem.org

Revision as of 21:45, 26 September 2012 by Korates (Talk | contribs)

Substrate Analytics

Summary

We tried to degrade our Substrates with the TVEL0 and our self produced Laccases. The HPLC results showed that the hormons are degradeble with our Laccases. Polycyclic Aromatic Hydrocarbons (PAHs) distingrate themself in the Britton buffer but with Laccases there is so little Anthracene that the LC-MS could not detect it. This means that probably the Laccase is able to degradate it. Due to time reasons we could not measure the Analgesics and Lindane which was also one of our Substrates to test but we have not had the opportunity. The spectrofluorophotometer data showed also that Ethinyl estradiol and Estradiol are degraded after Laccase treatment.


Contents


Spectrofluorophotometer Anaylses

We analyzed our degradation procuts with the Spectrofluorophotometer. As you can see it in the pictures above the Ethinyl estradiol and Estradiol are degraded over night. Figure 1 shows the Ethiny estradiol without Laccase, Figure 2 shows that no more Ethinyl estradiol is left in the sample after the degradation and new peaks appear possibly degradation products. On Figure 3 you can see the Estradiol control without Laccases. Like Ethinyl estradiol our Estradiol peak does not appear in the degradation and new peaks can be seen indicating that thoose are new degradation products.

Figure 1: Ethinyl estradiol control without Laccases
Figure 2: Ethinyl estradiol degradation. There are some peaks probabyl degradation products. The Ethinyl estradiol peak disapeard


Figure 3: Estradiol control without Laccases

Liquid chromatography–mass spectrometry

Dilution series

Our Substrates are soluble in Methanol. We set our standarts into a concentration of 1 mg mL-1. The detection limit for the LC-MS showed that a concentration of 10µg/l for the Substrates Esteron and Estradiol is the highest concentration of detection. Same limit of detection was used for Ethinyl estradiol and Anthracen for degradation. We only used thoose four Substrates. For all LC-MS preperations we used the T. versicolor Laccases. The dilution series were set in Methanol and 50%Acetonitril- 50% Water.

Figure 1: Anthracen calibration curve
Figure 2: Estrone calibration curve


Degradation results

The TVEL0 was able to degradate the synthetic estradiol (fig. 1) and we cannot say it for sure but also Anthracen (fig 3.). Our Ethinylestradiol calibration curve showed that it is stable in the media we used (fig 2.). Anthracen distingrates itself in the Britton Puffer but with Laccases there is less Anthracen measured in the LC-MS indicating our Laccase is able to degradate it (fig. 4). Estrone (fig. 5) and Estradiol (fig. 6) were degrade as well. On Estrone we could not identify any degradation products. The reason for this could be that the products are not detectable with LC-MS. We could identify peaks in the degradation of Estradiol but were not able to identify them. On the following figures you can see the results of our LC-MS measurments. The controls in different media showed no changes in concentration.

Figure 1: Ethinylestradiol + TVEL0 measured by LC-MS. You can see that the over night sample has onyl half sub>2of the substrate left.
Figure 3: Anthracen + TVEL0. In the over night sample there is undetacable less Anthracen.

Figure 4: The negative control for Anthracen without Laccases. As you can see the concentration of Anthracen goes down. This is caused by the Britton Puffer
Figure 2: Our Ethinylestradiol negative control without Laccase. Variation on the peaks is probably caused by an pipetting mistake.

Figure 5: Estrone + TVEL0. The peaks shows that Estrone is degradated but still the over night sample is still in the detection
Figure 6: Estradiol degradation analyses with mass-spectrometry. On the X-axis is listed the retention time. Y-axis the mass/charge ratio. From white to red is the intensity of the measured samples. On the figure above you can see the t0 Estradiol while the figure below shows the degradation. The analytes retendet in min 1 are the media soilling. Since we know that the retention time of Estradiol is on min 5 we could see that over night no more Estradiol is left and some other peaks appear which are probably degradation products


We also tried to measure the degradation with mass-spectrometry. Since quantification via mass-spectrometry is difficult to ionization of the analytes, we quantified our substrats by UV-light. Nevertheless, mass spectrometry enables identification of degradation products. We anaylzed estradiol degradation in detail (fig. 6) resulting in possible chemical compounds generated. Until now we can not say clearly how estradiol degradation functions, but with more time degradation products can maybe identified

High performance liquid chromatography

Dilution series

Figure 1.1:The detection range of ethinyl estradiol. Concentrations between 0.1 µg ml -1 and 3 µg ml -1 a/partinfo> in a Bioengineering NFL22 with a total volume of 6re detecable.

At first we mesured dilution series of all different substrates. While estradiol and ethinyl estradiol where easy to mesure, we didnt succed often with the estrone calibration curves. This was caused by its bad solubility. The retention time for estradiol is 5.8 minutes, for estrone 4.7 minutes and for ethinyl estradiol 5.2 minutes. For all estrogens we could use the same extinction and emmission values: Ex 230, Em 310.


Figure 1.2:The calibration curve of ethinyl estradiol. Concentrations between 0.1 µg ml -1 and 3 µg ml -1.
Figure 1.3:Calibration curve for estradiol.


The next substrate class where the analgesics. These three substrates have different optimal extinction and emission values. Additional difficulties occured with naproxene and ibuprofen. Instead of one single peak we found two for each substrate, and none of them correlated with the used concentration. With diclofenac we are still not sure which extinction and emmission values are to use. We found different values and aditionaly we analysed it with a spectrofluorometer but this has also shown no clear peak for diclofenac.

Three of the four PAH´s have the same extinction and emmission values. Simular to the estrogens, the PAH calibration curves are easy to generate. Naphthalene has a retention time of 9.6 minutes and its detection range is also 0.1 to 2.5 µg*mL-1. Acenaphthene with a retention time of 15.1 minutes and phenantrene with a retention time of 17 minutes have maximal detectable concentration of 1.5 µg*mL-1.

Anthracene will be mesured later.

Figure 1.4:BPUL degradated estradiol. Overleyed chromatograms from different timepoints. The first peak caused by the solvent.


Negative controls

Figure 2.1:The PAH´s naphthalene, acenaphthene and phenantrene in BR-buffer at 30 °C. The startconcentration was 1 µg mL -1 for all PAH´s. After 1 houre nearly all PAH´s decayed completely.
Figure 2.2:Naphthalene decay in four different conditions. Dissolved in methanol, dissolved in acetonitrile, with BR-buffer and with BR-buffer together with ABTS


The results of our negative controls of the first Polycyclic aromatic hydrocarbon, PAH, degradations showed, that PAH´s decay without laccase with a high speed. So we take a closer look at the three PAH´s in Britton Robinson (BR)-buffer. The result can be seen in figure 2.1. After one hour most of the used substrates decayed.

The next step was to check if and which substance cause the decay. In this test we dissolved naphthalene in acetonitrile and in methanol and compared the pure solvents with the influence of the BR-buffer and BR-buffer with ABTS. With pure methanol or acetonitrile naphthalene decays slow in comparison to BR-buffer. In BR-buffer with or without ABTS the decay happens faster and under nearly the same velocity. So BR-buffer seems to be a bad choice to test if our laccases degrade PAH´s.

Estradiol and ethinyl estradiol did not decay in BR-buffer, as shown by the negative controls in degradation experiments.



Degradation

Figure 3.1:Comparison between two of our laccases BPUL and ECOL with the purchased laccase TVEL0 under ABTS influence.
Figure 3.2:Purchased laccase TVEL0 degrades ethinyl estradiol. Estradiol in BR-buffer without laccase as negative control.


Degradation reactions with ABTS showed the expected results. "Team Activity Test" already showed, that the laccases have the ability to oxidise ABTS. The fact that oxidised ABTS reacts chemicaly with the substrates, explains that all of our active laccases have the ability to degrade ethinly estradiol and other substrates. The potential of the purchased laccase TVEL0 is much higher, shown in figure 3.2. BPUL has not the same potential as the purchased laccase. But BPUL degrades estradiol without the influence of ABTS.

Figure 3.3:Our laccase BPUL in unknown concentration degrades estradiol. Estradiol in BR-buffer without laccase as negative control.


Outlook

Anthracene, lindane and diclofenac are to be detected with the HPLC. Ibuprofen and naproxen need a good calibration curve. For naphthalene, acenaphthene and phenantrene we have to test different buffers or lower the temperature too keep ist more stable. We have only tested BPUL and ECOL so far. "Team Activity Test" showed that TTHL is active so we can test this laccase for the different substrates. Also there will be the trametis versicolor laccases TVEL5, TVEL10, TVEL13 and TVEL20. Additional we want to determine kcat/km for the degradable substances.
On the LC-MS we did not measure our Substrates with our self produced Laccases. If we had the opportunity, the would test our self produced Laccases with the Substrates. Besides we did not measure all Substrates they need to be measured as well to identify degradation products.

55px Logo merck.jpg BioCircle.JPG Bielefeld2012 Evonik.jpg Bielefeld2012 Baxter.png Logo knauer.jpg Logo iit.jpg Bielefeld2012 BIEKUBA.jpg Logo biometra.jpg Logo bio-nrw.png Bielefeld2012 Logo ERASynbio.jpg