Team:Cambridge/RiskAssessments/Gelelectrophoresis
From 2012.igem.org
(Created page with "{{Template:Team:Cambridge/CAM_2012_TEMPLATE_HEAD_SAFETY}} =Gel Electrophoresis= The protocol for this technique be found here an...")
Newer edit →
Revision as of 15:57, 13 August 2012
Gel Electrophoresis
The protocol for this technique be found here and MSDS for the reagents used can be found here.
Risks
SYBR Safe - SYBR safe is very dangerous to work with, causing skin damage, eye damage and respiratory tract damage, even from a single exposure. Everything that comes into contact with it must be treated as hazardous chemical waste. This must not be disposed of in the same way as biological waste, it should be taken to the stores office where it will be disposed of by the univeristy's contractors.
Gel preparation - the TAE buffer and agarose are not inherently dangerous but to be effectively mixed together they need to be heated, usually in a microwave. To fully dissolve the agarose, the mixture must be heated to a temperature too hot to touch. The container must therefore be handled with a heat proof glove. There is also a danger that the mixture could overheat and this is extremely dangerous. The mixture should therefore be heated gradually, in small bursts and then mixed to heat to the minimum possible temperature to completely dissolve. The lid of the container must be on, but not screwed tight as tight as possible to allow for gas expansion as the mixture heats up.