Line 95: Line 95:
:*Lane 4 + 5: Vector DNA from pJS130 - Chloramphenicol resistance marker - 9.0kbp fragment expected
:*Lane 4 + 5: Vector DNA from pJS130 - Chloramphenicol resistance marker - 9.0kbp fragment expected
-
:*Lane 6: Postitive control - 1.9kbp fragment expected
+
:*Lane 6: Postitive control (replicates) - 1.9kbp fragment expected
*Riboswitch DNA was successfully amplified. However, vector DNA was not. Given that the postive control was also successful, it seems likely that something went wrong with some stage before the PCR amplification. We will try to rectify the problem tomorrow.
*Riboswitch DNA was successfully amplified. However, vector DNA was not. Given that the postive control was also successful, it seems likely that something went wrong with some stage before the PCR amplification. We will try to rectify the problem tomorrow.

Revision as of 17:03, 18 July 2012

Home Team Official Team Profile Project Parts Submitted to the Registry Modeling Notebook Safety Attributions Sponsors
Week: 1 2 3 4
Diary Lab book

Contents

Monday

Transformation of bacillus and e.coli with lux genes from 2010


Tuesday

Induction of lux genes in e.coli with IPTG


PCR of vector


  • Plasmid PJS 130 used as our backbone for isolating the magnesium riboswitch.
  • Primers:
  • Forward: TTCAAAACATGACCTATGACgtcgcagagtatgccg
  • Reverse: cctccctctgctaaaacACAAGGCATTAACACTACAT
  • PCR settings:
  • 95 °C - 6mins
  • 98 °C - 10secs
  • 58 °C - 45secs
  • 72 °C - 180secs
  • Repeat above 35x
  • 72 °C - 5mins
  • 25 °C - 1min

PCR of riboswitch DNA from bacillus genome


  • Colony of strain check what the strain was used as template for this experiment.
  • Primers used:
  • Forward: cggagggagacgattttgTGTTCCGTAATTGTGATGTAAG
  • Reverse: acaccggcatactctgcgacGTCATAGGTCATGTTTTGAACC
  • PCR settings - as above (run in parallel).

Wednesday

Gel electrophoresis of PCR products


  • PCR fragments for Mg2+ riboswitch from yesterday separated on gel. 90mins at 100V.
Results of gel electrophoresis on PCR fragments from yesterday. 550bp fragments in lanes 2+3 were remove before the image was taken
  • Lane 1: Ladder
  • Lane 2 + 3: Riboswitch DNA from genome (replicates) - 550bp fragment expected.
  • Lane 4 + 5: Vector DNA from pJS130 - Chloramphenicol resistance marker - 9.0kbp fragment expected
  • Lane 6: Postitive control (replicates) - 1.9kbp fragment expected
  • Riboswitch DNA was successfully amplified. However, vector DNA was not. Given that the postive control was also successful, it seems likely that something went wrong with some stage before the PCR amplification. We will try to rectify the problem tomorrow.

Purification of riboswitch DNA from gel


  • Successful riboswitch DNA extracted from gel and purified using a minelute column. DNA frozen for later Gibson assembly.

Thursday