Team:WashU/Protocols/Ligation
From 2012.igem.org
(Difference between revisions)
(→General Ligation Protocol) |
BrianBasco (Talk | contribs) |
||
Line 3: | Line 3: | ||
=General Ligation Protocol= | =General Ligation Protocol= | ||
- | 1. Gather ingredients below and label PCR tube. (Total volume is 10ul)<br> | + | <dl>1. Gather ingredients below and label PCR tube. (Total volume is 10ul)<br> |
- | + | <dd>1ul 10x T4 ligase buffer | |
- | + | <dd>6:1 molar ratio of insert to vector (appx 10ng vector) | |
- | + | <dd>ddh20 (to bring total volume to 10ul) | |
- | + | <dd>0.5ul T4 Ligase | |
+ | </dl> | ||
2. Add appropriate amount of deionized H2O to sterile 0.6 mL tube<br> | 2. Add appropriate amount of deionized H2O to sterile 0.6 mL tube<br> | ||
3. Add 1 μL ligation buffer to the tube. <br> | 3. Add 1 μL ligation buffer to the tube. <br> |