Team:UCSF/Violacein Results

From 2012.igem.org

(Difference between revisions)
Line 20: Line 20:
<br><regulartext>
<br><regulartext>
-
Before we started our experiments, we obtained a violacein standard from Sigma-Aldrich,<a href="http://www.sigmaaldrich.com/catalog/product/sigma/v9389?lang=en&region=US">Item:V9389-1MG </a><span>. We used this standard to measure the absorbance of violacein at varying concentrations, obtaining the standard curve shown below. <br>
+
Before we started our experiments, we obtained a violacein standard from Sigma-Aldrich,<a href="http://www.sigmaaldrich.com/catalog/product/sigma/v9389?lang=en&region=US">Item:V9389-1MG </a><span>. We used this standard to measure the absorbance of violacein at varying concentrations, obtaining the standard curve shown below. Full wavelength scans were obtained, but as shown by previous iGEM teams (<a href="https://2009.igem.org/Team:Cambridge/Project/Violacein">Cambridge 2009 </a>) the maximum absorbance of violacein is seen at 575nm and is reported here. <br>
<img align="left" style="margin-bottom:8px; width:755px;height:410px; padding:0;" src="https://dl.dropbox.com/u/24404809/iGEM%202012/igem%202012%20website%20photos/violacein/100212vio_std_cf.jpg">
<img align="left" style="margin-bottom:8px; width:755px;height:410px; padding:0;" src="https://dl.dropbox.com/u/24404809/iGEM%202012/igem%202012%20website%20photos/violacein/100212vio_std_cf.jpg">
Line 33: Line 33:
<P>
<P>
<regulartext>
<regulartext>
-
The details of growth and sample analysis can be found on our protocols page.
+
The details of growth and sample analysis can be found on our protocols page. <p>
 +
 
 +
<regulartext>
 +
 
 +
<img align="left" style="margin-bottom:8px; width:755px;height:410px; padding:0;" src="https://dl.dropbox.com/u/24404809/iGEM%202012/igem%202012%20website%20photos/violacein/100112vio_wavelengths.jpg">

Revision as of 16:39, 3 October 2012

Production of Violacein by an E. coli Co-Culture


Before we started our experiments, we obtained a violacein standard from Sigma-Aldrich,Item:V9389-1MG . We used this standard to measure the absorbance of violacein at varying concentrations, obtaining the standard curve shown below. Full wavelength scans were obtained, but as shown by previous iGEM teams (Cambridge 2009 ) the maximum absorbance of violacein is seen at 575nm and is reported here.
During our experiments we worked with several different strains of E. coli, each containing plasmids with different violacein constructs:

  • Strain 1: pcdfDuet+VioABE
  • Strain 2:pcdfDuet+VioDC
  • Strain 3: pcdfDuet:VioABE+VioDC (full operon)
  • The details of growth and sample analysis can be found on our protocols page.