Team:Washington/Protocols/Plas DNA.
From 2012.igem.org
(Difference between revisions)
(→Isolation of Plasmid DNA (miniprep)) |
(→Equipment Necessary) |
||
Line 31: | Line 31: | ||
#Centrifuge | #Centrifuge | ||
- | #Miniprep Kit | + | #QIAGEM Miniprep Kit |
#Microcentrifuge tubes | #Microcentrifuge tubes |
Revision as of 00:50, 3 October 2012
Isolation of Plasmid DNA (miniprep)
- Gently vortex overnight culture(s) to mix cells.
- Pipet ~1 mL of cells into a labeled microcentrifuge tube. Pellet the cells by centrifuging at 6000 X g.
- Carefully pour off the supernatant without disturbing the pelleted cells.
- Resuspend the pelleted cells in 250 μL of refrigerated buffer P1.
- Add 250 μL of buffer P2 and thoroughly mix the tube by inverting 4-6 times.
- Add 350 μL of buffer N3 and immediately (but gently) mix the tube by inverting 4-6 times.
- Centrifuge the sample at ~17000 X g for 10 minutes.
- Pour/Pipet the supernatant into a spin column (blue).
- Centrifuge the sample for ~ 1 minute. Discard the flow-through.
- Wash the sample by adding 500 μL buffer PB and centrifuge for ~ 1 minute.
- Wash the sample by adding 750 μLbuffer PE and centrifuge for ~ 1 minute.
- Discard the flow-through and centrifuge the sample for an additional 1 minute.
- To Elute the DNA, place the spin column in a clean 1.5 μL (labeled) microcentrifuge. Add 30 μL of buffer EB and let Stand for 1 minute!
- Centrifuge the sample for 1 minute.
- Record the DNA concentration using the nanodrop program.
- Open the nanodrop program on the lab computer.
- Select "DNA"
- Once the program loads, pipet 1 ul of distilled H20 onto the machine.
- Hit "collect" in order to run the sample to clean the machine.Wipe off the remaining water with a kimwipe.
- Pipet 1 ul of EB buffer onto the machine. Hit "collect" in order to run the sample to clean the machine.Wipe off the remaining buffer with a kimwipe.
- Pipet 1 ul of a miniprep sample onto the machine. Hit "collect" in order to run the sample to clean the machine.Wipe off the remaining sample with a kimwipe, and record the concentration of the miniprep (ng/ul).
- Repeat the process of pipeting a sample and "collected" until all samples have been measured.
Equipment Necessary
- Centrifuge
- QIAGEM Miniprep Kit
- Microcentrifuge tubes