Result: None of the pcr products contained the desired product. It is not sure if this is due to wrong primers or not approprate working taq polymerase.
Result: None of the pcr products contained the desired product. It is not sure if this is due to wrong primers or not approprate working taq polymerase.
 +
 +
 +
Emeraldo
 +
 +
Cut the pSac-Cm and purified terminator PCR product with EcoRI and HindIII. Cut pSac-Cm was run on the gel and cut at the correct cut size and purified from the gel. Ligation of cut pSac-Cm with cut terminator and then transformation of E.coli DH5alpha with the ligation product.
<html>
<html>

Revision as of 14:39, 25 September 2012





Tom

PCRed the different promotors alsT 150, 250, 300, 500 and Fnr to GFP.

Result: None of the pcr products contained the desired product. It is not sure if this is due to wrong primers or not approprate working taq polymerase.


Emeraldo

Cut the pSac-Cm and purified terminator PCR product with EcoRI and HindIII. Cut pSac-Cm was run on the gel and cut at the correct cut size and purified from the gel. Ligation of cut pSac-Cm with cut terminator and then transformation of E.coli DH5alpha with the ligation product.