User:DrJones1935/2 August 2012
From 2012.igem.org
(Difference between revisions)
(Created page with "====I. Prepare for Gel Extraction of a PCR Product from 27 Jul 2012==== *'''Make Gel:''' :*Measure out 1.00721 g of agarose and add to a 250 mL E-flask :*Add 50 mL of 0.5x TBE ...") |
DrJones1935 (Talk | contribs) m (→RESULTS) |
||
Line 102: | Line 102: | ||
=====''RESULTS''===== | =====''RESULTS''===== | ||
- | |||
''Concentration:'' | ''Concentration:'' |
Latest revision as of 01:45, 4 October 2012
Contents |
I. Prepare for Gel Extraction of a PCR Product from 27 Jul 2012
- Make Gel:
- Measure out 1.00721 g of agarose and add to a 250 mL E-flask
- Add 50 mL of 0.5x TBE buffer and swirl to mix
- Cover flask with a Kimwipe and microwave for ~1 minute until clear
- Allow to cool to ~60 oC
- Immediately pour gel into tray with modified combs (3 taped together for large well)
- Allow to solidify, then remove the comb and tape and place the tray in the gel box with the wells closer to the black electrode
- Make sure it is submerged in TBE buffer
- Load Gel:
- Mix 3 samples (+2,+3,+4) in one microcentrifuge tube with 27 uL buffer. Load ~140 uL into one lane and the rest into another.
- Load on gel according to the following chart:
Lane 1 | 2 | 3-5 |
---|---|---|
Invitrogen 1kb+ ladder | Cassette (~10 uL) | Cassette (~140 ul) |
- Run Gel:
- Close gel box and turn on power pack
- Run gel at 30 V for ~1 hr, 20 min
- Run gel at 75 V until the markers have reached bottom of the gel
- Cut Gel:
- Remove gel from box and cut along lanes to separate the 10 uL lane from the 140 uL lane.
- Return 140 uL lane to the gel box
- Post-stain with EtBr
- Place 10 uL lane in 200 mL of 0.5 ug/mL EtBr solution for 15 minutes
- Remove EtBr solution and wash with 200 mL of dH2O for 10 minutes
- Image Gel
- View 10 uL lane under UV to identify band of interest
- Use a clean razor blade to nick gel where the band is
- Excise Gel Fragments
- Match 140 uL lane to the 10 uL lane
- Using the 10 uL lane as a guide, cut out the band from the 140 uL lane
II. QIAquick Gel Extraction Protocol
- Weigh each gel slice in a colorless 15 mL conical tube:
Cassette (+1) |
---|
485 mg |
- Add 3 volumes Buffer QG to 1 volume of gel
Cassette (+1) |
---|
1455 uL |
- Incubate in 50 oC water bath for 10-12 minutes until all gel has dissolved. Vortex to help mix.
- Note: The solutions were all yellow, OK to proceed
- Add 1 volume 100% isopropanol to samples and mix by inversion
Cassette (+1) |
---|
485 uL |
- Apply sample to a QIAquick column 800 uL at a time. Centrifuge for 1 minute at 13000 rpm, discard flow-through, and repeat until all of the sample has passed through the column
- Add 500 uL of Buffer QG to the QIAquick columns and centrifuge for 1 minute, discard flow-through
- Add 750 uL of Buffer PE to the QIAquick columns and let the column stand for 5 minutes on the bench
- Centrifuge for 1 min and discard flow through
- Centrifuge again for 1 minute
- Transfer the columns to clean microcentrifuge tubes
- Elute DNA by adding 30 uL of Buffer EB to the center of the column and let stand for 4 minutes
- Centrifuge for 1 minute
III. Measure the Concentration of Extracted DNA
- Bring sample and Buffer EB bottle upstairs to Take3 plate reader
- Add 2 uL of each sample according to the following chart:
Blank (EB) | Blank |
Blank | Blank |
Cassette | (empty) |
- Use the program to blank the machine and measure sample concentrations
RESULTS
Concentration:
Sample | Concentration (ng/uL) | Approx. volume (uL) | Approx. total (ug) |
---|---|---|---|
Cassette | 7.769 | ~28 | 0.22 |
IV. Image Post-Stained Gel
RESULTS
Source: Media:Srk_2012-08-02_18hr_08min.tif
Feature | Expected Size (bp) |
---|---|
Cassette | 5152 |
V. QIAquick PCR Purification Protocol
- Add 5 volumes Buffer PB to 1 volume of reaction, mix
Reaction (+5) | Volume PB |
---|---|
50 uL | 250 uL |
- Note: The solutions were all yellow, OK to proceed
- Apply sample to a QIAquick column, centrifuge for 1 minute at 13000 rpm, discard flow-through
- Add 750 uL of Buffer PE to the QIAquick column, centrifuge for 1 min and discard flow through
- Centrifuge again for 1 minute
- Transfer the column to clean microcentrifuge tube
- Elute DNA by adding 30 uL of Buffer EB to the center of the column and let stand for 1 minute
- Centrifuge for 1 minute, store DNA at 4 oC
VI. PCR Amplification of Cassette
- Mix Reagents:
- Mix according to the following table, where PP = PCR purified template and GE = gel extracted template
- | PP 2 | PP 5 | PP 10 | GE 2 | GE 5 | GE 10 | |
---|---|---|---|---|---|---|---|
Reagent | (uL) | (uL) | (uL) | (uL) | (uL) | (uL) | |
water | 33.5 | 31.5 | 28.5 | 23.5 | 31.5 | 28.5 | 23.5 |
5x Phusion HiFi buffer | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
10 mM dNTP mix | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
10 uM primer (F) | 2.5 (pBf) | 2.5 (pBf) | 2.5 (pBf) | 2.5 (pBf) | 2.5 (pBf) | 2.5 (pBf) | 2.5 (pBf) |
10 uM primer (R) | 2.5 (pBr) | 2.5 (pBr) | 2.5 (pBr) | 2.5 (pBr) | 2.5 (pBr) | 2.5 (pBr) | 2.5 (pBr) |
Template | 0 | 2 | 5 | 10 | 2 | 5 | 10 |
Phusion HiFi polymerase | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
- Run PCR
Step | Temp (oC) | Time |
---|---|---|
1 | 94 | 4 m |
2 | 94 | 30 s |
3 | 66 | 30 s |
4 | 72 | 1.5 m |
10 | 72 | 7 m |
11 | 4 | ∞ |
(left overnight)