'''Table 1''' - NanoDrop results of purified plasmids, prepared by Gibson Assembly, including DNA concentration (ng/uL), and 260/280 and 260/230 absorbance values.
{| border="3" cellpadding="4" cellspacing="0" align="center" style="width: 55%; height: 400px"
{| border="3" cellpadding="4" cellspacing="0" align="center" style="width: 55%; height: 400px"
|-
|-
Line 81: Line 82:
|-
|-
| align="center"| 2
| align="center"| 2
-
| align="center"| 17.5
+
| align="center"| 17.50
| align="center"| 1.90
| align="center"| 1.90
| align="center"| 2.48
| align="center"| 2.48
 +
 +
|-
 +
| align="center" rowspan="9" | 13 Aug
 +
| align="center" rowspan="3" | 3CE
 +
| align="center"| 1
 +
| align="center"| 43.60
 +
| align="center"| 1.92
 +
| align="center"| 2.27
 +
 +
|-
 +
| align="center"| 2
 +
| align="center"| 38.30
 +
| align="center"| 1.89
 +
| align="center"| 1.67
 +
 +
|-
 +
| align="center"| 3
 +
| align="center"| 62.20
 +
| align="center"| 1.91
 +
| align="center"| 1.77
 +
 +
|-
 +
| align="center" rowspan="3" | 4KE
 +
| align="center"| 1
 +
| align="center"| 49.50
 +
| align="center"| 1.82
 +
| align="center"| 1.23
 +
 +
|-
 +
| align="center"| 2
 +
| align="center"| 32.30
 +
| align="center"| 1.78
 +
| align="center"| 0.91
 +
 +
|-
 +
| align="center"| 3
 +
| align="center"| 14.40
 +
| align="center"| 1.89
 +
| align="center"| 1.75
 +
 +
|-
 +
| align="center" rowspan="3" | 5CE
 +
| align="center"| 1
 +
| align="center"| 71.10
 +
| align="center"| 1.76
 +
| align="center"| 1.17
 +
 +
|-
 +
| align="center"| 2
 +
| align="center"| 92.10
 +
| align="center"| 1.78
 +
| align="center"| 1.17
 +
 +
|-
 +
| align="center"| 3
 +
| align="center"| 56.70
 +
| align="center"| 1.86
 +
| align="center"| 2.08
|}
|}
<br/>
<br/>

Latest revision as of 01:23, 23 September 2012



NanoDrop Results


Table 1 - NanoDrop results of purified plasmids, prepared by Gibson Assembly, including DNA concentration (ng/uL), and 260/280 and 260/230 absorbance values.

Date Plasmid Colony # Concentration (ng/uL) 260/280 260/230
6 Aug 3K 1 50.70 1.89 2.32
2 61.40 1.88 1.97
7 Aug 1C 1 61.90 1.90 2.30
2 52.10 1.90 2.42
3 52.00 1.91 2.11
4 69.00 1.88 2.15
5 65.60 1.89 2.38
6 58.70 1.88 2.40
3K 1 6.80 2.16 0.56
11 Aug 2K 1 10.90 1.98 2.68
2 17.50 1.90 2.48
13 Aug 3CE 1 43.60 1.92 2.27
2 38.30 1.89 1.67
3 62.20 1.91 1.77
4KE 1 49.50 1.82 1.23
2 32.30 1.78 0.91
3 14.40 1.89 1.75
5CE 1 71.10 1.76 1.17
2 92.10 1.78 1.17
3 56.70 1.86 2.08