Chris was working from home on the Rocket hub site, then had a prio ingagement
<p> (11:00 am) Continuation of the DNA extraction. Finishing plating up all the CSE kits onto minimal media and polystyrene mix.
<p> (11:00 am) Continuation of the DNA extraction. Finishing plating up all the CSE kits onto minimal media and polystyrene mix.
-
<p> (12:00 pm) All the CSE kits are plated and incubating in the warm room ready to be analysed and hopefully come up with a positive result.</div>
+
<p> (12:00 pm) All the CSE kits are plated and incubating in the warm room ready to be analysed and hopefully come up with a positive  
 +
<p> (16:00 am) iGEM Weekly meeting, after this Chris prepaired the overnights ready for starting the next Genomic tip tomorrow, while Dr badge and will preparied the lab ready for tomorrow after the leak.
 +
result.</div>
<h3 class="calendar"> &nbsp; &nbsp; Tuesday 14th August 2012</h3>
<h3 class="calendar"> &nbsp; &nbsp; Tuesday 14th August 2012</h3>
<div class="day">
<div class="day">
-
No entry for this date.
+
Will and chris,
 +
 
 +
Setting up to run the gel tomorrow, as well as finishing off the genomic tip number 2 prep. This included Chris and Dr Badge trying to improvise a method to generate +ve pressure on the tip to a rate of 20-40 drips per min, as it was taking in excess of 24 hours for 10ml to flow through the coloumb we thought this was necessary ( protocol say's for slow rates to use a adapter and apply the pressure)
 +
As we didn't have an adapter, or siringe plunger that was the correct size we inprovised, testing out with the used coloumb 1 different ways to apply the pressure, be that by adding a cut down siringe to the top of the coloumb which then could accomodate a plundger, and the other method of using a oversized plundger rubber, using a thumb to press it into the top of the coloumb to create the pressure needed. The second method was used this time to finish off the coloumb as there was only about 2ml to run through. After this we prepired the samples to load onto the gel tomorrow.
 +
 
 +
for the samples, we did a 4x diltuion of each aliquat, as well as the pure DNA, just incase there is a large amount of genomic DNA in the samples. these are stored in the 5 degrees room ready for morning
</div>
</div>
Line 209: Line 217:
Will and chris,
Will and chris,
-
09:00 Chris loaded and we are now running the gel electrophoresis of the aliquats taken along the geome extraction of E.coli to make sure we have been doing it correctly. There seems to be very low yeild from the maxi prep so are trouble shooting the problems with the tip e.t.c and altering some of the steps from the priscribed QIAGEN genome extraction kit.
+
<p> (9:00 am) Chris loaded and we are now running the gel electrophoresis of the aliquats taken along the geome extraction of E.coli to make sure we have been doing it correctly. There seems to be very low yeild from the maxi prep so are trouble shooting the problems with the tip e.t.c and altering some of the steps from the priscribed QIAGEN genome extraction kit.
 +
 
 +
<p> (11:15 am) boiling the RNase for 10 minutes to make sure that it re conforms to the RNase rather than DNase which it can change conformation into after a long period of time. This may have been the case with the previous 2 genomic tips, so trying this to see if we can gain a higher yeid this time. Gel is still running and is now about half way. Will is now using the nanodrop spectrophotometer to see if there is DNA in the aliquats and the pure DNA elution.  
-
11:15 boiling the RNase for 10 minutes to make sure that it re conforms to the RNase rather than DNase which it can change conformation into after a long period of time. This may have been the case with the previous 2 genomic tips, so trying this to see if we can gain a higher yeid this time. Gel is still running and is now about half way. Will is now using the nanodrop spectrophotometer to see if there is DNA in the aliquats and the pure DNA elution.  
+
<p> (12:00 am) Genomic tip 2 gel results were blank, ( immage to follow) so we're thinking it was the RNase as there was no DNA in even the aliquat 1 from the gel. Markers and our mini prep showed the DNA ran as such. Now we are preparing the cultures chris made two nights ago for another Maxi prep with the E.coli, however with the boiled RNase and other alterations to the method. to start we are peleting the bacteria, OD600 3.25 scaled from a 10x dilution, so we have 2.6x10^9 cells per ML, the max for the prep is 1x10^11 cells so we are using 28ML of our culture, working out at 7.28x10^10 cells which is in the limit. the cultures have been balanced equally and are now spinning in the centrifuge at 2600G which is as high as the centrifuge will go with this size falcon tubes, as this is slightly under the 3000G recomended, we are spinning for longer to maximise the size of the pellet. Once the supernatant has been removed, we will re-spin to make sure any remaining liquid has drained to the bottom to then pippet this off to make sure there is no supernatant left.
</div>
</div>

Revision as of 11:30, 15 August 2012

    Wednesday 1st August 2012

(9:30 am) Several members of the team are given wrong start times, so only 1 student arrived in the lab at 9:30, however with the work needed to be done all the rest of the team are quickly on their way.

(10:30 am) With everyone now in the lab it turns out a lot of the work planned for today has to wait until tomorrow. This is due to the ''Pseudomonas'' strains needed to be grown in a rich luria broth before we can spin it into a pellet and then run the DNA extraction.

(11:40 am) With all the bacteria placed in the 15ml corning tubes, and placed in the orbital shaker all of today's labwork is complete. Now the team is going to finish the recording for the rockethub video as some scenes need to be retaken, then do some individual research/work.

(13:30 pm) After consulting with a supervisor and having a long meeting over lunch the team has decided several directions that is needed to go in. One member is testing the cooling times of a water bath that will be used in the hybridizing process of making our DNA libraries, and to start selecting out of the DNA genes that are in both our Pseudomonas and the NB26 strain that definitely degrades polystyrene. A couple of members are looking through protocol and methods to use with the DNA extraction.

    Thursday 2nd August 2012

(9:30 am) An early start finishing all the protocol and work needed to start making the DNA libraries.

(10:00 am) ''E. coli'' is placed into 7ml of LB media and put into the warm room to grow overnight and be used as the test tomorrow to check the DNA extraction process before using the ''Pseudomonas'' species.

(11:30 am) The protocol for tomorrow's practicals is determined, for the test of the DNA extraction, as well as dilutions to check the growth so there is a measurable amount that the ''Pseudomonas'' can be compared to, so in future to measure the amount of ''Pseudomonas'' the team has it can simply be spectrophotometrized.

(4:00 pm) Made the ''E. coli'' into a 50ml broth to grow overnight for the dilutions and spectrophotometry.

    Friday 3rd August 2012

(9:00 am) Action stations. All labwork is go. Today there are 2 experiments going: the DNA extraction test and the dilutions to test the method works. Once these are done, the team knows what works and doesn't work for the real experiments on ''Pseudomonas'' early next week.

(10:00 am) Na na na na na na na na BATMAN!

(10:30 am) The team splits into 2 groups and goes to do the tasks with a qill of iron.

The half doing the dilutions to make the growth curve left our dedicated bit of lab space and headed into one of the supervisors labs with a good spectrophotometer and space to work with the bacteria.

Protocol:

1. Put 1ml of culture into a spectrophotomer and take a reading at 600nm. Record this as time = 0. Start the timer.

2. At same time, take an aliquot of 100microl and put in eppindorf marked as time 0, 10^-1 dilution. Add 900microl of buffer and mix, then take 100 microl from this solution and add to next eppendorf, marked time 0, 10^-2 dilution and so on to 10^-9.

3. Pipette 100microl of dilutions 10^-4 to 10^-9 onto similarly labelled pre-prepared agar plates and spread them.

4. Repeat step 2 every 40 minutes and step 4 every 2 hours (3 divisions of E. coli) until the end of time.

5. Leave plates to grow, then count the number of colonies growing on the most concentrated plate where colonies are distinguishable. Multiply up to the true concentration, then multiply by 10. This is colonies/ml.

6. Draw graph to see correlation and check against known correlation to see if it has worked.

(16:30 pm) The dilutions and CFU count part of the experiment is finished, there is 6 hours of readings for the CFU count as well as plates for 0, 2 and 4 hours.

    Saturday 4th August 2012

No entry for this date.

    Sunday 5th August 2012

The only thing needed to be done today is help the technician gave the team. This involved producing ''E. coli'' overnight cultures for the DNA extraction and digest.

    Monday 6th August 2012

(9:30 am) Today the team is going to extract the genome and start the DNA digest of the ''E. coli'' to test the DNA extraction kit and procedure that the team has identified to use.

This is a big step that if works, can then be applied to the ''Pseudomonas'' strains that are growing. So that once the NB26 strain arrives it can be compared straight away to give an idea which genes could be involved in the degredation of polystyrene and to help start narrowing our search.

The overnight cultures of E. coli were then analysed using the spectrophotometer to give an initial bacterial cell count before the digest.

(12:30pm) The results for yesterday's experiment is back. Unfortunately the data that was collected is not enough to create a graph to simply show us what the bacteria cell count is from reading an absorbance.

The new protocol for today's experiment that will tell the team this data is:

1. Inoculate 49.9ml of broth with 0.1ml of the overnight bacteria colony. Mix, start timer, and immediately do 3 and 4.

2. Put 1ml of culture into a spectrophotomer and take a reading at 600nm. Record this as time = 0. Start a timer.

3. At same time, take an aliquot of 100microl and put in eppindorf marked as time 0, 10^-1 dilution. Add 900microl of buffer and mix, then take 100 microl from this solution and add to next eppendorf, marked time 0, 10^-2 dilution and so on to 10^-7.

4. Pipette 100microl of dilutions 10^-5 to 10^-7 onto similarly labelled pre-prepared agar plates and spread them.

5. Repeat steps 3-5 every 40min (1 doubling of E. coli) (labelling time appropriately) until the end of time.

6. Leave plates to grow, then count the number of colonies growing on the most concentrated plate where colonies are distinguishable. Multiply up to the true concentration, then multiply by 10. This is colonies/ml.

7. Draw graph to see correlation and check against known correlation to see if it has worked.

(13:30pm) After finally finishing all the reading up and gathering of ingredients, the DNA extraction process is finally started. Protocol is as mentioned in the QIAGEN Genomic DNA Handbook.

Almost as soon as it was started the first few sections were complete and the cells needed to be left in a 37oC water bath for a while so the team members had to wait again. And then had to wait again after adding different buffer while the cell extract was left at 50oC.

(15:00) The current step is using the genomic tip protocol to extract DNA. Unfortunately, the flow rate is very slow so this may take a while until the DNA can be washed and eluted.

(17:30) Today's refinement of the growth curve experiment worked. Well at least the protocol did, the actual experiment failed but after talking to the supervisor in a group meeting, the team realised what went wrong so it would work tomorrow. Just before finishing, 3ml of luria broth was innoculated with a single colony of ''E. coli'' as well as the plates being made up.

    Tuesday 7th August 2012

(8:00 am) A very early start for part of the group working on fixing the dilutions experiment. In for 8am, and started at 8:30 for a long day's practical.

(14:30 pm) The final set of plates and spectrophotometry readings have been taken. Now they can grow overnight to see if it works.

    Wednesday 8th August 2012

(9:30 am) The plates had grown, but unfortunately they had all grown a ridiulous amount. It turns out that the luria broth had been contaminated with some bacteria. The group didn't realize this as it was thought some of the nutrients had suspended like what had happened to our minimal media beforehand. This means another experiment must be done to see if it can finally be done right.

(11:30 am) The final dilutions experiment was started, but it needed time to grow out of lag phase. Just before lunch it still hadn't started to grow so the group was starting to despair, but after a long lunch break it had finally started to grow.

(14:30 pm) The final series of plating and spectrophotometry has started, only time will tell if it is finally right.

    Thursday 9th August 2012

(11:00 am) It worked! The final dilutions experimen came back with close to expected results so the plates could be counted and a graph made to show the cell count against absorbance.

    Friday 10th August 2012

No entry for this date.

    Saturday 11th August 2012

No entry for this date.

    Sunday 12th August 2012

No entry for this date.

    Monday 13th August 2012

Chris was working from home on the Rocket hub site, then had a prio ingagement

(11:00 am) Continuation of the DNA extraction. Finishing plating up all the CSE kits onto minimal media and polystyrene mix.

(12:00 pm) All the CSE kits are plated and incubating in the warm room ready to be analysed and hopefully come up with a positive

(16:00 am) iGEM Weekly meeting, after this Chris prepaired the overnights ready for starting the next Genomic tip tomorrow, while Dr badge and will preparied the lab ready for tomorrow after the leak. result.

    Tuesday 14th August 2012

Will and chris, Setting up to run the gel tomorrow, as well as finishing off the genomic tip number 2 prep. This included Chris and Dr Badge trying to improvise a method to generate +ve pressure on the tip to a rate of 20-40 drips per min, as it was taking in excess of 24 hours for 10ml to flow through the coloumb we thought this was necessary ( protocol say's for slow rates to use a adapter and apply the pressure) As we didn't have an adapter, or siringe plunger that was the correct size we inprovised, testing out with the used coloumb 1 different ways to apply the pressure, be that by adding a cut down siringe to the top of the coloumb which then could accomodate a plundger, and the other method of using a oversized plundger rubber, using a thumb to press it into the top of the coloumb to create the pressure needed. The second method was used this time to finish off the coloumb as there was only about 2ml to run through. After this we prepired the samples to load onto the gel tomorrow. for the samples, we did a 4x diltuion of each aliquat, as well as the pure DNA, just incase there is a large amount of genomic DNA in the samples. these are stored in the 5 degrees room ready for morning

    Wedesnday 15th August 2012

Will and chris,

(9:00 am) Chris loaded and we are now running the gel electrophoresis of the aliquats taken along the geome extraction of E.coli to make sure we have been doing it correctly. There seems to be very low yeild from the maxi prep so are trouble shooting the problems with the tip e.t.c and altering some of the steps from the priscribed QIAGEN genome extraction kit.

(11:15 am) boiling the RNase for 10 minutes to make sure that it re conforms to the RNase rather than DNase which it can change conformation into after a long period of time. This may have been the case with the previous 2 genomic tips, so trying this to see if we can gain a higher yeid this time. Gel is still running and is now about half way. Will is now using the nanodrop spectrophotometer to see if there is DNA in the aliquats and the pure DNA elution.

(12:00 am) Genomic tip 2 gel results were blank, ( immage to follow) so we're thinking it was the RNase as there was no DNA in even the aliquat 1 from the gel. Markers and our mini prep showed the DNA ran as such. Now we are preparing the cultures chris made two nights ago for another Maxi prep with the E.coli, however with the boiled RNase and other alterations to the method. to start we are peleting the bacteria, OD600 3.25 scaled from a 10x dilution, so we have 2.6x10^9 cells per ML, the max for the prep is 1x10^11 cells so we are using 28ML of our culture, working out at 7.28x10^10 cells which is in the limit. the cultures have been balanced equally and are now spinning in the centrifuge at 2600G which is as high as the centrifuge will go with this size falcon tubes, as this is slightly under the 3000G recomended, we are spinning for longer to maximise the size of the pellet. Once the supernatant has been removed, we will re-spin to make sure any remaining liquid has drained to the bottom to then pippet this off to make sure there is no supernatant left.

    Thursday 16th August 2012

No entry for this date.

    Friday 17th August 2012

No entry for this date.

    Saturday 18th August 2012

No entry for this date.

    Sunday 19th August 2012

No entry for this date.

    Monday 20th August 2012

No entry for this date.

    Tuesday 21st August 2012

No entry for this date.

    Wedesnday 22nd August 2012

No entry for this date.

    Thursday 23rd August 2012

No entry for this date.

    Friday 24th August 2012

No entry for this date.

    Saturday 25th August 2012

No entry for this date.

    Sunday 26th August 2012

No entry for this date.

    Monday 27th August 2012

No entry for this date.

    Tuesday 28th August 2012

No entry for this date.

    Wednesday 29th August 2012

No entry for this date.

    Tuesday 30th August 2012

No entry for this date.

[edit]