Team:EPF-Lausanne/Protocol/GelExtraction

From 2012.igem.org

(Difference between revisions)
Line 19: Line 19:
empty lane on both sides to avoid contamination, these bands get quite big).
empty lane on both sides to avoid contamination, these bands get quite big).
When the gel has finished running, put it on a UV light, and locate the correct
When the gel has finished running, put it on a UV light, and locate the correct
-
band. Cut it out (with a razorblade, try cutting away as much agar as possible
+
band. Cut it out (with a razorblade) and put it in an Eppendorf (consider using a 2ml one).
-
while retaining the DNA) and put it in an Eppendorf (consider using a 2ml one).
+
Then apply the instructions in your kit.
Then apply the instructions in your kit.
We used Macherey-Nagel's "Nucleospin® Gel and PCR clean-up" kit.
We used Macherey-Nagel's "Nucleospin® Gel and PCR clean-up" kit.
Its manual can be found here: [http://www.mn-net.com/Portals/8/attachments/Redakteure_Bio/Protocols/DNA%20clean-up/UM_PCRcleanup_Gelex_NSGelPCR.pdf Gel and PCR clean-up Manual]
Its manual can be found here: [http://www.mn-net.com/Portals/8/attachments/Redakteure_Bio/Protocols/DNA%20clean-up/UM_PCRcleanup_Gelex_NSGelPCR.pdf Gel and PCR clean-up Manual]
 +
 +
== Tips ==
 +
 +
* Cut away as much Agar as possible. It will play havoc with the spincolumn's filter
 +
and reduce the yield.
 +
* Minimize the DNA's exposure to the UV-light. UV will damage DNA and have negative effects
 +
on any subsequent reactions (for example, [[Team:EPF-Lausanne/Protocol/Ligation|ligations]]
 +
can be 10'000x less effective when DNA has been exposed to too much UV light [http://openwetware.org/wiki/DNA_Ligation]
{{:Team:EPF-Lausanne/Template/ProtocolFooter}}
{{:Team:EPF-Lausanne/Template/ProtocolFooter}}
<noinclude>{{:Team:EPF-Lausanne/Template/Footer}}</noinclude>
<noinclude>{{:Team:EPF-Lausanne/Template/Footer}}</noinclude>

Revision as of 22:10, 24 September 2012

Protocol: Gel Extraction


A gel extraction is used to select a fragment of DNA of a specific length out of a solution composed of different fragments (ideally the difference in length between the wanted fragment and the closest-sized fragment should be more than 200bp). These fragments are often obtained after a digestion.

Start with a lot of DNA (at least 2 ug of DNA to get reasonable yields), and load a gel with it (if possible, leave an empty lane on both sides to avoid contamination, these bands get quite big). When the gel has finished running, put it on a UV light, and locate the correct band. Cut it out (with a razorblade) and put it in an Eppendorf (consider using a 2ml one). Then apply the instructions in your kit.

We used Macherey-Nagel's "Nucleospin® Gel and PCR clean-up" kit. Its manual can be found here: [http://www.mn-net.com/Portals/8/attachments/Redakteure_Bio/Protocols/DNA%20clean-up/UM_PCRcleanup_Gelex_NSGelPCR.pdf Gel and PCR clean-up Manual]

Tips

  • Cut away as much Agar as possible. It will play havoc with the spincolumn's filter

and reduce the yield.

  • Minimize the DNA's exposure to the UV-light. UV will damage DNA and have negative effects

on any subsequent reactions (for example, ligations can be 10'000x less effective when DNA has been exposed to too much UV light [http://openwetware.org/wiki/DNA_Ligation]