Team:MIT/MaterialsAndMethods
From 2012.igem.org
(Difference between revisions)
Line 119: | Line 119: | ||
PLACEHOLDER TEXT | PLACEHOLDER TEXT | ||
<br> | <br> | ||
- | *Adapted from Invitrogen <i> Lipofectaime® 2000 Reagent Product Manual</i> | + | *Adapted from Invitrogen <i> Lipofectaime® 2000 Reagent Product Manual.</i> |
http://tools.invitrogen.com/content/sfs/manuals/lipofectamine2000_man.pdf | http://tools.invitrogen.com/content/sfs/manuals/lipofectamine2000_man.pdf | ||
</br> | </br> | ||
Line 128: | Line 128: | ||
<h1>RNA Transfection</h1> | <h1>RNA Transfection</h1> | ||
<br> | <br> | ||
- | *Adapted from Invitrogen <i> Transfecting Stealth™ or siRNA into Mammalian Cells using Lipofectamine™ RNAiMAX </i> | + | *Adapted from Invitrogen <i> Transfecting Stealth™ or siRNA into Mammalian Cells using Lipofectamine™ RNAiMAX. </i> |
+ | http://www.invitrogen.com/etc/medialib/en/filelibrary/pdf.Par.34731.File.dat/Transfecting_Stealth_using_Lipofectamine_RNAiMAX.pdf | ||
</br> | </br> | ||
Revision as of 21:24, 12 September 2012
Gate Anneals
Room Temperature Annealing
- Mix gate and output in a 1.2:1 ratio in a tube.
- Cover the tube in foil, if you didn't use an opaque/black tube.
- Leave the tube on a bench top overnight.
Annealing With Heatblock
- Preheat the heat block to 95°C, add water to the well you will be using.
- Put a piece of styrofoam (covered with foil) on the heat block. Make sure the temperature is still at 95°C, and doesn't jump
- Mix gate and output in a 1.2:1 ratio in a tube, put it in the heat block.
- Cover again with the styrofoam, set the heat block to RT.
- 5. Wait until the block cools. It will probably not reach RT, but will be at around 30°C after a few hours. Turn the block off completely and wait for a bit (1h).
N.B. It may be possible to anneal using a lower maximum temperature (say, 80°C), as long as it is higher than the melting temperature of the oligos.
*Adapted from Qian L, Winfree E. Scaling up digital circuit computation with DNA displacement cascades. , Science. 2011 Jun 3;332(6034):1196-201.
- Mix gate and output in a 1.2:1 ratio in a tube.
- Cover the tube in foil, if you didn't use an opaque/black tube.
- Leave the tube on a bench top overnight.
Annealing With Heatblock
- Preheat the heat block to 95°C, add water to the well you will be using.
- Put a piece of styrofoam (covered with foil) on the heat block. Make sure the temperature is still at 95°C, and doesn't jump
- Mix gate and output in a 1.2:1 ratio in a tube, put it in the heat block.
- Cover again with the styrofoam, set the heat block to RT.
- 5. Wait until the block cools. It will probably not reach RT, but will be at around 30°C after a few hours. Turn the block off completely and wait for a bit (1h).
N.B. It may be possible to anneal using a lower maximum temperature (say, 80°C), as long as it is higher than the melting temperature of the oligos.
*Adapted from Qian L, Winfree E. Scaling up digital circuit computation with DNA displacement cascades. , Science. 2011 Jun 3;332(6034):1196-201.
- Preheat the heat block to 95°C, add water to the well you will be using.
- Put a piece of styrofoam (covered with foil) on the heat block. Make sure the temperature is still at 95°C, and doesn't jump
- Mix gate and output in a 1.2:1 ratio in a tube, put it in the heat block.
- Cover again with the styrofoam, set the heat block to RT.
- 5. Wait until the block cools. It will probably not reach RT, but will be at around 30°C after a few hours. Turn the block off completely and wait for a bit (1h).
N.B. It may be possible to anneal using a lower maximum temperature (say, 80°C), as long as it is higher than the melting temperature of the oligos.
*Adapted from Qian L, Winfree E. Scaling up digital circuit computation with DNA displacement cascades. , Science. 2011 Jun 3;332(6034):1196-201.
Plate Reader Studies
Kinetic Studies
- Prepare wells: 100 µL 1X TAE, 12.5 mM Mg2+ buffer; 10 nM 100 µL RNA-ROX (gate); 10 nM 100 µL gate:output complex; 10 nM 100 µL gate:output complex.
- Measure fluorescence of all wells for 1 minute (5 seconds between measurements).
- Add 1 µL of the buffer to the buffer and gate wells. Add 1 µl of 1 µM input S6 to the first gate:output well; add 1 µL of 1 µM input S1 to the second gate:output well. Note: Mix well by pipetting into the well, after adding input shake the plate by doing a sort of swirling motion in a plane. If possible, set the plate reader to do this for you for 3 seconds with a 1 second rest time.
- Measure fluorescence of all wells for 10 minutes (5 seconds between measurements).
*Adapted from Qian L, Winfree E. Scaling up digital circuit computation with DNA displacement cascades. , Science. 2011 Jun 3;332(6034):1196-201.
DNA Transfection
PLACEHOLDER TEXT*Adapted from Invitrogen Lipofectaime® 2000 Reagent Product Manual. http://tools.invitrogen.com/content/sfs/manuals/lipofectamine2000_man.pdf
RNA Transfection
*Adapted from Invitrogen Transfecting Stealth™ or siRNA into Mammalian Cells using Lipofectamine™ RNAiMAX. http://www.invitrogen.com/etc/medialib/en/filelibrary/pdf.Par.34731.File.dat/Transfecting_Stealth_using_Lipofectamine_RNAiMAX.pdf