Team:MIT/MaterialsAndMethods

From 2012.igem.org

(Difference between revisions)
Line 76: Line 76:
<div class="bio" id="iv1bio">
<div class="bio" id="iv1bio">
<h1> Gate Anneals </h1>
<h1> Gate Anneals </h1>
-
<h2> Room Temperature Annealing <h2>
+
<h2><b> Room Temperature Annealing </b><h2>
-
&nbsp;<OL>
+
<OL>
<LI>Mix gate and output in a 1.2:1 ratio in a tube.</LI>
<LI>Mix gate and output in a 1.2:1 ratio in a tube.</LI>
-
<LI>;Cover the tube in foil, if you didn't use an opaque/black tube.</LI>
+
<LI>Cover the tube in foil, if you didn't use an opaque/black tube.</LI>
<LI>Leave the tube on a bench top overnight.</LI>
<LI>Leave the tube on a bench top overnight.</LI>
</OL>
</OL>
 +
<h2><b> Room Temperature Annealing </b><h2>
 +
<OL>
 +
<LI>Preheat the heat block to 95C, add water to the well you will be using.</LI>
 +
<LI>Put a piece of styrofoam (covered with foil) on the heat block. Make sure the temperature is still at 95C, and doesn't jump</LI>
 +
<LI>Mix gate and output in a 1.2:1 ratio in a tube, put it in the heat block.</LI>
 +
<LI>Cover again with the styrofoam, set the heat block to RT.</LI>
 +
<LI>5. Wait until the block cools. It will probably not reach RT, but will be at around 30C after a few hours. Turn the block off completely and wait for a bit (1h).</LI>
 +
</OL>

Revision as of 23:14, 9 September 2012

iGEM 2012

Bacterial

  • Placeholder1
  • Placeholder2

In Vitro

  • Gate Anneals
  • Plate Reader Studies

Mammalian

  • DNA Transfection
  • RNA Transfection

Gate Anneals

Room Temperature Annealing

  1. Mix gate and output in a 1.2:1 ratio in a tube.
  2. Cover the tube in foil, if you didn't use an opaque/black tube.
  3. Leave the tube on a bench top overnight.

Room Temperature Annealing

  1. Preheat the heat block to 95C, add water to the well you will be using.
  2. Put a piece of styrofoam (covered with foil) on the heat block. Make sure the temperature is still at 95C, and doesn't jump
  3. Mix gate and output in a 1.2:1 ratio in a tube, put it in the heat block.
  4. Cover again with the styrofoam, set the heat block to RT.
  5. 5. Wait until the block cools. It will probably not reach RT, but will be at around 30C after a few hours. Turn the block off completely and wait for a bit (1h).