<h1>Project Description</h1>
+
<h1>sEnsiColi: A tunable and reliable ultra-sensitive detector</h1>
-
<p>
+
 
-
The Grenoble iGEM team intends to build an ultra sensitive detector. The goal is to produce a detector that can hugely amplify a given signal. It consists of three modules:<br/>
+
Multi-resistant bacteria are a worldwide issue which in a very near future will have
-
<br/>
+
huge impacts on our societies and ways diagnosis and prevention will be performed.
 +
In this optic, the Grenoble iGEM team has built an ultra-sensitive pathogen detector.  
 +
<br/><br/>It consists of three interconnected modules:
<ol>
<ol>
-
    <li>the first gets the signal</li>
+
<li>Detection</li>
-
    <li>the second amplifies it</li>
+
<li>Amplification/Communication</li>
-
    <li>the third sends the output</li>
+
<li>Output</li>
</ol>
</ol>
<br/>
<br/>
-
The detection module is a membrane receptor that once activated by a chemical compound actuates an amplification loop. The loop enhances the cell response efficiency.<br/>
+
The detection module consists of a recombinant membrane receptor that, once activated, actuates an amplification loop. The amplification system contains a genetic feed forward loop, which filters out false  
-
The amplification system contains a genetic feed forward loop. It acts as a biologic loud filter aiming at reducing false positive outputs.  
+
positive outputs. Once amplified and filtered, the signal is transmitted to neighboring  
-
Once amplified and filtered the signal is transmitted to the neighboring bacteria.  
+
bacteria via a diffusible molecule. In turn, the amplification loop is triggered which
-
In this way a noticeable fluorescent emission is generated. <br/>
+
leads to the production of a measurable fluorescence output. <br/>
-
<br/>
+
<br/>The design of our
-
<h4>Scheme of the concept</h4>
+
network is easily adaptable to different input signals by using other receptor domains.
-
<img src="https://static.igem.org/mediawiki/2012/9/9d/Schema1.png" alt="Scheme of the concept" />
+
<!-- <center> <h4>Scheme of the concept</h4> </center>
-
 
+
<center><img src="https://static.igem.org/mediawiki/2012/9/9d/Schema1.png" alt="Scheme of the concept" style="horizontal-align: center;"/></center>
-
<h4>Theoretical response of the device depending on the input signal</h4>
+
-
<img src="https://static.igem.org/mediawiki/2012/c/cf/Schema2.png" alt="Theoretical response of the device depending on the input signal" />
+
-
</p>
+
<center> <h4>Theoretical response of the device depending on the input signal</h4> <br/>
 +
<img src="https://static.igem.org/mediawiki/2012/c/cf/Schema2.png" alt="Theoretical response of the device depending on the input signal" style="horizontal-align: center;"/></center> -->
</section>
</section>
 +
</div>
</body>
</body>
</html>
</html>
 +
{{:Team:Grenoble/script}}
 +
{{:Team:Grenoble/menu}}

Latest revision as of 00:59, 25 September 2012

iGEM Grenoble 2012

Project

sEnsiColi: A tunable and reliable ultra-sensitive detector

Multi-resistant bacteria are a worldwide issue which in a very near future will have huge impacts on our societies and ways diagnosis and prevention will be performed. In this optic, the Grenoble iGEM team has built an ultra-sensitive pathogen detector.

It consists of three interconnected modules:
  1. Detection
  2. Amplification/Communication
  3. Output

The detection module consists of a recombinant membrane receptor that, once activated, actuates an amplification loop. The amplification system contains a genetic feed forward loop, which filters out false positive outputs. Once amplified and filtered, the signal is transmitted to neighboring bacteria via a diffusible molecule. In turn, the amplification loop is triggered which leads to the production of a measurable fluorescence output.

The design of our network is easily adaptable to different input signals by using other receptor domains.