Team:Cornell/testing/project/wetlab/4/1

From 2012.igem.org

(Difference between revisions)
 
(15 intermediate revisions not shown)
Line 33: Line 33:
Testing & Results
Testing & Results
<ul>
<ul>
 +
<li>
 +
<a href="https://2012.igem.org/Team:Cornell/testing/project/wetlab/4/7">Parts</a>
 +
</li>
<li class="active">
<li class="active">
<a href="https://2012.igem.org/Team:Cornell/testing/project/wetlab/4/1">Reactors</a>
<a href="https://2012.igem.org/Team:Cornell/testing/project/wetlab/4/1">Reactors</a>
Line 70: Line 73:
<div class="six columns">
<div class="six columns">
<h3>Overview of Characterization in Bioelectrochemical Systems</h3>
<h3>Overview of Characterization in Bioelectrochemical Systems</h3>
-
As described in the <a href="https://2012.igem.org/Team:Cornell/testing/project/wetlab/2">Chassis</a> section, <i>S. oneidensis</i> MR-1 is capable of shuttling electrons through the Mtr pathway to reduce extracellular metals because of the negative free energy change associated with these redox reactions. Thus, to encourage <i>Shewanella</i> to transfer electrons to an electrode, we poise the potential of an electrode in a three electrode system, controlled by a potentiostat, so that electron transfer is energetically favorable to the organism. [[LINK TO THE PAGE ON THE POTENTIOSTAT]]. In short, a potentiostat works by setting the potential of a working electrode (WE) with respect to a Ag/AgCl reference electrode (RE) by injecting current through a counter electrode (CE). These electrodes can be seen in the schematic representation of our single-compartment bioelectrochemical reactors shown below.
+
As described in the <a href="https://2012.igem.org/Team:Cornell/testing/project/wetlab/2">Chassis</a> section, <i>S. oneidensis</i> MR-1 is capable of shuttling electrons through the Mtr pathway to reduce extracellular metals because of the negative free energy change associated with these redox reactions. Thus, to encourage <i>Shewanella</i> to transfer electrons to an electrode, we poise the potential of an electrode in a three electrode system, controlled by a potentiostat, so that electron transfer is energetically favorable to the organism. In short, a potentiostat works by setting the potential of a working electrode (WE) with respect to a Ag/AgCl reference electrode (RE) by injecting current through a counter electrode (CE). These electrodes can be seen in the schematic representation of our single-compartment bioelectrochemical reactors shown to the right.
Line 86: Line 89:
<br>
<br>
Because we are interested in continuous monitoring of contaminants, characterization focused on the operation of reactors in continuous flow setup, wherein reactors approached steady state current outputs at each level of analyte. In general, all experiments were set up in bench-scale reactors provided by the Angenent Lab, with a constant fluid volume of 120mL and a consistent electrode-surface area. All characterization experiments began at an analyte concentration of zero, as media was fed to the system at a constant rate of 18 mL/min. Once a system reached steady state&#8212;for a period of greater than three system retention times&#8212;the analyte concentration in the feed tank was increased. By repeating this process after new steady state current outputs were reached, we were able to characterize the current response of our reporter and control strains to either arsenic-containing compounds or naphthalene, as appropriate.  
Because we are interested in continuous monitoring of contaminants, characterization focused on the operation of reactors in continuous flow setup, wherein reactors approached steady state current outputs at each level of analyte. In general, all experiments were set up in bench-scale reactors provided by the Angenent Lab, with a constant fluid volume of 120mL and a consistent electrode-surface area. All characterization experiments began at an analyte concentration of zero, as media was fed to the system at a constant rate of 18 mL/min. Once a system reached steady state&#8212;for a period of greater than three system retention times&#8212;the analyte concentration in the feed tank was increased. By repeating this process after new steady state current outputs were reached, we were able to characterize the current response of our reporter and control strains to either arsenic-containing compounds or naphthalene, as appropriate.  
 +
<br><br>
 +
After initial characterization of our arsenic- and naphthalene-sensing strains, <b>we have shown that our arsenic sensor works as expected</b>, producing higher levels of steady-state current in response to arsenite salts. However, more trials are needed in order to construct a reliable calibration curve.
Line 96: Line 101:
<div class="twelve columns">
<div class="twelve columns">
<h3>First Lessons Learned: Control Reactors</h3>
<h3>First Lessons Learned: Control Reactors</h3>
-
In order to enhance the field-deployability of our final device, we initially decided to feed our reactors with LB, since a very concentrated LB source fed at a low flow rate could sustain our field reactors for extended periods of time without taking up much physical space. However, upon setting up control reactors&#8212;both in batch and continuous flow operation&#8212;we discovered that wild type <i>S. oneidensis</i> MR-1 produced significantly less current when fed with LB than M4&#8212;a commonly used media for <i>Shewanella</i>-inoculated bioelectrochemical systems.<br>
+
In order to enhance the field-deployability of our final device, we initially decided to feed our reactors with LB, since a very concentrated LB source fed at a low flow rate could sustain our field reactors for extended periods of time without taking up much physical space. However, upon setting up control reactors&#8212;both in batch and continuous flow operation&#8212;we discovered that wild type <i>S. oneidensis</i> MR-1 produced significantly less current when fed with LB than M4&#8212;a commonly used media for <i>Shewanella</i>-inoculated bioelectrochemical systems, as illustrated for batch operation by the figure below.<br>
<img class="inline" src="https://static.igem.org/mediawiki/2012/1/1c/LBvM4_small.png">
<img class="inline" src="https://static.igem.org/mediawiki/2012/1/1c/LBvM4_small.png">
<b> Fig. 1. Current production over time is plotted for batch reactors inoculated with wildtype <i>S. oneidensis</i> MR-1 growing on M4 media (blue) and LB media (green). Maximum current production from M4-fed <i>Shewanella</i> is much greater than that from LB-fed.</b><br><br>
<b> Fig. 1. Current production over time is plotted for batch reactors inoculated with wildtype <i>S. oneidensis</i> MR-1 growing on M4 media (blue) and LB media (green). Maximum current production from M4-fed <i>Shewanella</i> is much greater than that from LB-fed.</b><br><br>
-
Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text. Text text text.  
+
When operated in a continuous flow setup, we observed the steady state current production from an LB fed reactor to be within the background noise of the setupM4&#8212;<i>i.e.</i>, an un-incoluated reactor was indistinguishable from a reactor inoculated with wildtype <i>S. oneidensis</i> MR-1. Because of this, we chose to use M4 media for all future characterization experiments, since optimization of signal-to-noise ratio is essential in the development of any sensing system.
</div>
</div>
Line 108: Line 113:
<div class="nine columns">
<div class="nine columns">
<h3>Naphthalene & Salicylate Sensing</h3>
<h3>Naphthalene & Salicylate Sensing</h3>
-
First characterized naphthalene sensors with salicylate, since our system indirectly senses naphthalene via salicylate.
+
 
-
<br>
+
Because we did not have time to confirm successful conjugation of our naphthalene-degrading plasmid into <i>Shewanella</i>, we focused our efforts on observing the response to salicylate of our naphthalene-sensing precursor strain (JG700 + pSAL). This strain contains the molecular machinery requisite to respond to salicylate, which&#8212;in our final system&#8212;is a metabolite produced as a result of naphthalene catabolism via the enzymes encoded by the <i>nah</i> operon. (To read more about our naphthalene sensor design, see our <a href="https://2012.igem.org/Team:Cornell/testing/project/wetlab/3/2">DNA Assembly</a> page.) <br>
-
Uninduced salicylate reporter produces same current as MR-1 in rich M4 media.
+
 
-
<br>
+
 
-
First attempt to diagnose problem: Switch to minimal M4... Producing higher current, but we're still not getting a salicylate response.
+
 
-
<br>
+
-
Next attempt: Poise the working electrode at a higher potential in attempt to get more MtrC and MtrA for MtrB to associate with. Didn't quite do the trick either.
+
-
<br>
+
</div>
</div>
<div class="three columns">
<div class="three columns">
-
<img src="http://placehold.it/250x250/331642">
+
<img src="http://upload.wikimedia.org/wikipedia/commons/thumb/8/81/Naphthalene-from-xtal-3D-balls.png/289px-Naphthalene-from-xtal-3D-balls.png">
</div>
</div>
 +
 +
Line 126: Line 130:
<img class="inline" src="https://static.igem.org/mediawiki/2012/6/60/SAME_I_invis_small.png">
<img class="inline" src="https://static.igem.org/mediawiki/2012/6/60/SAME_I_invis_small.png">
<b> Fig. 2. Current production over time is plotted for continuous flow reactors inoculated with our salicylate reporter strain (blue) and wildtype <i>S. oneidensis</i> MR-1 (green). Both duration of transient period and value of saturating current are approximately equal for reactors corresponding to both strains. </b><br><br>
<b> Fig. 2. Current production over time is plotted for continuous flow reactors inoculated with our salicylate reporter strain (blue) and wildtype <i>S. oneidensis</i> MR-1 (green). Both duration of transient period and value of saturating current are approximately equal for reactors corresponding to both strains. </b><br><br>
 +
 +
 +
<div class="twelve columns">
 +
As seen above, our un-induced salicylate sensing strain produces approximately the same steady state current as wildtype <i>Shewanella</i>, suggesting that leaky expression of MtrB from uninduced promoter activity is enough to saturate current output. This can be understood in terms of the complete Mtr pathway, since metal-reduction activity requires a functional complex of MtrA, MtrB, and MtrC&#8212;as described in the <a href="https://2012.igem.org/Team:Cornell/testing/project/wetlab/2">Chassis</a> section page. Since there is only so much MtrC and MtrA in the cell, increasing MtrB activity saturates as free MtrC and MtrA is sequestered and localized.
 +
</div>
 +
 +
 +
</div><div class="twelve columns">
</div><div class="twelve columns">
-
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aenean rutrum aliquam ipsum, quis lobortis ante vestibulum eu. Nullam eget est justo. Fusce commodo arcu a dui bibendum aliquet. Sed justo eros, dictum quis dictum a, laoreet ut urna. Duis in felis at felis tempor rutrum et sed metus. In sollicitudin adipiscing nibh, eu euismod lectus faucibus eget. Cras ut nulla non velit consequat venenatis in ac velit. Etiam a elit justo. Etiam gravida nulla sit amet eros suscipit at auctor orci porta.
+
 
 +
 
 +
<img class="inline" src="https://static.igem.org/mediawiki/2012/8/80/Point3_invis_small.png">
 +
<b> Fig. 3. Current production over time is plotted for continuous flow reactors inoculated with our salicylate reporter strain (blue) and wildtype <i>S. oneidensis</i> MR-1 (green). Both duration of transient period and value of saturating current are approximately equal for reactors corresponding to both strains. </b><br><br>
 +
 
 +
 
</div>
</div>
Line 141: Line 158:
<div class="row last-ele" id="item4">
<div class="row last-ele" id="item4">
-
<div class="three columns">
+
 
-
<img src="http://placehold.it/250x250/331642">
+
<div class="twelve columns">
-
</div>
+
-
<div class="nine columns">
+
<h3>Arsenic Sensing</h3>
<h3>Arsenic Sensing</h3>
-
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aenean rutrum aliquam ipsum, quis lobortis ante vestibulum eu. Nullam eget est justo. Fusce commodo arcu a dui bibendum aliquet. Sed justo eros, dictum quis dictum a, laoreet ut urna. Duis in felis at felis tempor rutrum et sed metus. In sollicitudin adipiscing nibh, eu euismod lectus faucibus eget. Cras ut nulla non velit consequat venenatis in ac velit. Etiam a elit justo. Etiam gravida nulla sit amet eros suscipit at auctor orci porta.
+
We chose to initially characterize our arsenic-sensing <i>Shewanella</i> by dosing with sodium arsenite, since the organism's native arsenate reductase activity would introduce a confounding variable in part characterization. After this initial characterization , we have shown that current is, indeed, upregulated in response to our analyte of interest. However, we should emphasize that this data is preliminary: Because of the care we took to establish a thorough Standard Operation Procedure for the handling of arsenic, we only had time for a single characterization trial, shown below in Fig. 4. Additionally, we plan on characterizing in response to both arsenate salts (to determine whether arsenate reductase activity is indeed confounding) and antimonite (to estimate the likelyhood of false positives).
 +
 
 +
 
</div>
</div>
<div class="twelve columns">
<div class="twelve columns">
<img class="inline" src="https://static.igem.org/mediawiki/2012/7/7f/SPplot1_small.png">
<img class="inline" src="https://static.igem.org/mediawiki/2012/7/7f/SPplot1_small.png">
-
<b> Fig. 2. Current production over time is plotted for continuous flow reactors inoculated with our salicylate reporter strain (blue) and wildtype <i>S. oneidensis</i> MR-1 (green). Both duration of transient period and value of saturating current are approximately equal for reactors corresponding to both strains. </b><br><br>
+
<b> Fig. 4. Current production over time is plotted for continuous flow reactors inoculated with our arsenic-sensing strain (JG700+p14k). Transient phases corresponding to arsenite concentrations of 100 &mu;M (blue) and 500 &mu;M (green)are shown. Before a potentiostat channel restart at time zero, basal current was recorded at approximately 4 &mu;A. We report induced current in percent of this basal response.    </b><br><br>
-
 
+
-
 
+
-
 
+
-
 
+
-
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Aenean rutrum aliquam ipsum, quis lobortis ante vestibulum eu. Nullam eget est justo. Fusce commodo arcu a dui bibendum aliquet. Sed justo eros, dictum quis dictum a, laoreet ut urna. Duis in felis at felis tempor rutrum et sed metus. In sollicitudin adipiscing nibh, eu euismod lectus faucibus eget. Cras ut nulla non velit consequat venenatis in ac velit. Etiam a elit justo. Etiam gravida nulla sit amet eros suscipit at auctor orci porta.
+
 +
It is also important to point out that we have not normalized any data to a per-cell basis. Because we are interested in a field-deployable system that produces greater <i>absolute</i> current in response to analyte, we did not record either optical density or colony forming units over time. However, while not a rigorous, we have observed a visible decrease in biomass for increasing concentrations of arsenite&#8212;as would be expected. Therefore, it is likely that an a per-cell basis, our arsenic sensing strains produce much more current that Fig. 4 would suggest. We plan on repeating characterization experiments in response to arsenite&#8212;both to generate a reliable transfer function relating current to arsenite concentration and to better understand the relationship between specific growth rate and MtrB production as a function of analyte concentration.
</div>
</div>

Latest revision as of 04:04, 4 October 2012

Reactor Testing

Overview of Characterization in Bioelectrochemical Systems

As described in the Chassis section, S. oneidensis MR-1 is capable of shuttling electrons through the Mtr pathway to reduce extracellular metals because of the negative free energy change associated with these redox reactions. Thus, to encourage Shewanella to transfer electrons to an electrode, we poise the potential of an electrode in a three electrode system, controlled by a potentiostat, so that electron transfer is energetically favorable to the organism. In short, a potentiostat works by setting the potential of a working electrode (WE) with respect to a Ag/AgCl reference electrode (RE) by injecting current through a counter electrode (CE). These electrodes can be seen in the schematic representation of our single-compartment bioelectrochemical reactors shown to the right.

Because we are interested in continuous monitoring of contaminants, characterization focused on the operation of reactors in continuous flow setup, wherein reactors approached steady state current outputs at each level of analyte. In general, all experiments were set up in bench-scale reactors provided by the Angenent Lab, with a constant fluid volume of 120mL and a consistent electrode-surface area. All characterization experiments began at an analyte concentration of zero, as media was fed to the system at a constant rate of 18 mL/min. Once a system reached steady state—for a period of greater than three system retention times—the analyte concentration in the feed tank was increased. By repeating this process after new steady state current outputs were reached, we were able to characterize the current response of our reporter and control strains to either arsenic-containing compounds or naphthalene, as appropriate.

After initial characterization of our arsenic- and naphthalene-sensing strains, we have shown that our arsenic sensor works as expected, producing higher levels of steady-state current in response to arsenite salts. However, more trials are needed in order to construct a reliable calibration curve.

First Lessons Learned: Control Reactors

In order to enhance the field-deployability of our final device, we initially decided to feed our reactors with LB, since a very concentrated LB source fed at a low flow rate could sustain our field reactors for extended periods of time without taking up much physical space. However, upon setting up control reactors—both in batch and continuous flow operation—we discovered that wild type S. oneidensis MR-1 produced significantly less current when fed with LB than M4—a commonly used media for Shewanella-inoculated bioelectrochemical systems, as illustrated for batch operation by the figure below.
Fig. 1. Current production over time is plotted for batch reactors inoculated with wildtype S. oneidensis MR-1 growing on M4 media (blue) and LB media (green). Maximum current production from M4-fed Shewanella is much greater than that from LB-fed.

When operated in a continuous flow setup, we observed the steady state current production from an LB fed reactor to be within the background noise of the setupM4—i.e., an un-incoluated reactor was indistinguishable from a reactor inoculated with wildtype S. oneidensis MR-1. Because of this, we chose to use M4 media for all future characterization experiments, since optimization of signal-to-noise ratio is essential in the development of any sensing system.

Naphthalene & Salicylate Sensing

Because we did not have time to confirm successful conjugation of our naphthalene-degrading plasmid into Shewanella, we focused our efforts on observing the response to salicylate of our naphthalene-sensing precursor strain (JG700 + pSAL). This strain contains the molecular machinery requisite to respond to salicylate, which—in our final system—is a metabolite produced as a result of naphthalene catabolism via the enzymes encoded by the nah operon. (To read more about our naphthalene sensor design, see our DNA Assembly page.)
Fig. 2. Current production over time is plotted for continuous flow reactors inoculated with our salicylate reporter strain (blue) and wildtype S. oneidensis MR-1 (green). Both duration of transient period and value of saturating current are approximately equal for reactors corresponding to both strains.

As seen above, our un-induced salicylate sensing strain produces approximately the same steady state current as wildtype Shewanella, suggesting that leaky expression of MtrB from uninduced promoter activity is enough to saturate current output. This can be understood in terms of the complete Mtr pathway, since metal-reduction activity requires a functional complex of MtrA, MtrB, and MtrC—as described in the Chassis section page. Since there is only so much MtrC and MtrA in the cell, increasing MtrB activity saturates as free MtrC and MtrA is sequestered and localized.
Fig. 3. Current production over time is plotted for continuous flow reactors inoculated with our salicylate reporter strain (blue) and wildtype S. oneidensis MR-1 (green). Both duration of transient period and value of saturating current are approximately equal for reactors corresponding to both strains.

Arsenic Sensing

We chose to initially characterize our arsenic-sensing Shewanella by dosing with sodium arsenite, since the organism's native arsenate reductase activity would introduce a confounding variable in part characterization. After this initial characterization , we have shown that current is, indeed, upregulated in response to our analyte of interest. However, we should emphasize that this data is preliminary: Because of the care we took to establish a thorough Standard Operation Procedure for the handling of arsenic, we only had time for a single characterization trial, shown below in Fig. 4. Additionally, we plan on characterizing in response to both arsenate salts (to determine whether arsenate reductase activity is indeed confounding) and antimonite (to estimate the likelyhood of false positives).
Fig. 4. Current production over time is plotted for continuous flow reactors inoculated with our arsenic-sensing strain (JG700+p14k). Transient phases corresponding to arsenite concentrations of 100 μM (blue) and 500 μM (green)are shown. Before a potentiostat channel restart at time zero, basal current was recorded at approximately 4 μA. We report induced current in percent of this basal response.

It is also important to point out that we have not normalized any data to a per-cell basis. Because we are interested in a field-deployable system that produces greater absolute current in response to analyte, we did not record either optical density or colony forming units over time. However, while not a rigorous, we have observed a visible decrease in biomass for increasing concentrations of arsenite—as would be expected. Therefore, it is likely that an a per-cell basis, our arsenic sensing strains produce much more current that Fig. 4 would suggest. We plan on repeating characterization experiments in response to arsenite—both to generate a reliable transfer function relating current to arsenite concentration and to better understand the relationship between specific growth rate and MtrB production as a function of analyte concentration.